DC 24V switching power:20VDC --- 36VDC;
RS485, RS232, MODBUS,REMOTE
Chinese or English displaying mode
milk analyse converter
Port: DALIAN
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 1000 Set/Sets per Month
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: protect boxes
Delivery Detail: 0-1days
1.1 Normal operating conditions
Standard of implement
The design, production and instrument of RV-100 series Electromagnetic Flowmeter Converter implement<JJG-1033-2007 Electromagnetic Flowmeters>.
General Specification of Converter
- Accuracy: 0.5%, 0.2%
- Relative Humidity:5%-90%;
- Digital communication: RS485, RS232, MODBUS,REMOTE
- Ambient temperature converter: -25°C to + 60°C
- Power supply: AC 85-265V, 45-63Hz, ≤20W; DC 11-40V
- Dissipation Power: <20W( After connecting sensor).
- Converter display and operation: four keys are available to set all parameters. External handheld or PC can be used to do the configuration. High resolution LCD display with backlight, empty pipe detection and self-diagnostic function are equipped in the converter.
1.2 Especial function
Connection Cable
Special cable is needed to connect the sensor and the converter for remote-type flowmeter. The cable length should not exceed 100 meters. A 10-meter cable is supplied free of charge and the rest is to be ordered.
Output Signals:
- Current output: fully-isolated, 4-20mA/0-10mA
- load resistance: 0-10mA: 0-1.5Kohm; 4-20mA: 0-750ohm.
Frequency output
bidirectional flow output. Frequency output is proportional to the flow percentage of the full range. The converter provides fully isolated transistor open collector frequency output ranged from 1 to 5000 Hz. The external DC power supply should not exceed 35V and maximum collector current is 250mA.
Pulse output
bidirectional flow output. The converter can output up to 5000cp/s pulse series, which is dedicated to external totalization. Pulse factor is defined as volume or mass per pulse. It can be set to 0.001L/p, 0.01L/p, 0.1L/p, 1L/p, 2L/p, 5L/p, 10L/p, 100L/p, 1m3/p, 10 m3/p, 100 m3/p or 1000 m3/p. Pulse width is selectable from auto, 10ms, 20ms, 50ms, 100ms, 150ms, 200ms, 250ms, 300ms, 350ms and 400ms. Photo-coupler isolated transistor open collector circuit is used for pulse output. The external DC power supply should not exceed 35V and maximum collector current is 250mA.
Flow direction indication
The converter is capable of measuring both forward and reverse flow and recognizing its direction. The converter outputs 0V low level for forward flow, while +12V high level for reverse flow.
Alarm output
Two channels of photo-coupler isolated open collector circuit are used for alarm signal output. There are two alarm outputs: high limit alarm and low limit alarm. The external DC power supply should not exceed 35V and maximum collector current is 250mA.
Damping constant
Damping time is selectable from 0.2 to 100s.
The health type electromagnetism flowmetre adopted new model of health type lining material and lining craft, hygiene request according to provisions craft, adopted stainless clad steel shell and the stainless clad steel card hoop connectivity at the same time, convenient electromagnetism flowmetre of quickly dismantle to unload, cleaning, make the electromagnetism flowmetre is in the process of using amid don't easily be polluted, and can effectively prevent°from measuring fluid odd-come-short measure to take care of to mediumly pile up, can extensively be applied to provisionses, such as ore spring, soy sauce, jam, beer, juice, rice wine and milk...etc. of realms, such as capacity manufacturing process and hygiene and chemical engineering...etc.
Fig.5(a) Remote-type key and display