Temperature Transmitters YTA320
1.the sensor type and the measurement range can be selected
2.High reliability
Port: Xi'an
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 1000 Piece/Pieces per Year
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: in carton
Delivery Detail: 5-6 weeks
Temperature Transmitters YTA3201.
1.YTA Series temperature transmitters convert the sensor signals to a unified signal, 4 to 20mA signal or FOUNDATION™ fieldbus.
2.This eliminates the drawbacks of wire resistance and signal noise that are often experienced with conventional temperature instruments, which must be connected by long extension lead wires or three-conductor cables to converters in an instrument panel room.
3.An additional feature is that both the sensor type and the measurement range can be selected.
4.Outstanding performance:Microprocessor-based sensing technology ensures high accuracy and stability.
High reliability: Dual-compartment housing realizes high resistance capability to harsh environments.
SIL Certification:YTA series temperature transmitters have been certified by TÜV NORD as being compliant with the requirements of the IEC61508 for SIL 2.
Variety of sensor inputs:The type of sensor input is user-selectable: thermocouples, RTDs, ohms, or DC milivolt.
Digital communication
5.The BRAIN and HART communication protocols are available.
The instrument configuration can be changed by the user with a BT200 terminal or HART communicator.
6.The YTA320 temperature transmitter also supports FOUNDATION fieldbus communication protocol.
Self-diagnostics function:Continuous self-diagnostics capability ensures long-term performance and lower cost of ownership.
7.LCD display with bargraph
The LCD display simultaneously displays a digital readout and a bargraph.
8.Dual universal inputs (Model YTA320)
The YTA320 can accept two thermocouple, RTD, ohm, or DC milivolt inputs. Differential or average temperature transmitter measurement can be selected. A sensor backup function automatically switches-over from the primary sensor to a backup if the sensor fails.
9.Specifications: Temperature Transmitters YTA320
Accuracy (typical) | YTA110: ±0.1% of span YTA310/320: ±0.05% of span |
Cold junction Compensation accuracy | (For T/C only) ±0.5 deg C (0.9 deg F) |
Power supply effect | ±0.005% of calibration span per volt |
Ambient temperature effect | ±0.1%/10 deg C (YTA110) |
Input signal | YTA110/YTA310: single input, YTA320: dual input Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt |
Output | Two wire 4 to 20 mA DC or FOUNDATION fieldbus signal (YTA320) |
Supply voltage | BRAIN and HART: 10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus: 9 to 32 V DC (9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO) |
Ambient temperature | Option code may affect limits -40 to 85 deg C (-40 to 185 deg F) -30 to 80 deg C (-22 to 176 deg F) with integral indicator |
Mounting | Optional mounting bracket can be used either for two-inch pipe or flat panel mounting. |
Weight | 1.2 kg (2.6lb) without integral indicator and mounting bracket. Integral indicator weighs 0.2kg (0.4lb). |
Degrees of protection | IP66, IP67 and NEMA 4X |
Certificates | CENELEC, CSA, FM, IECEx or TIIS |
SIL Certificate | Certified by TÜV NORD in compliance with the IEC61508 SIL 2 capability for single transmitter use. |