1.Temperature measuring range: -80 C - +600 C
2.Protection tube material: 1Cr18Ni9Ti
3.Protection tube Diameter: 60,100,150
Port: XINGANG
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Wooden Case
Delivery Detail: within 2 weeks
Measuring Range °C | Application | |
For industry & Commerce | For Laboratory | |
-80¬+40 | √ | √ |
+40¬+80 | √ | √ |
0¬50 | √ | √ |
0¬100 | √ | √ |
0¬150 | √ | √ |
0¬200 | √ | √ |
0¬300 | √ | √ |
0¬400 | √ | - |
0¬500 | √ | - |
10.Ambient Condition for Normal Operation
Working Place | Temperature °C | Relative Humidity % |
Sheltered Place | -25¬+25 | 5¬100 |
Outdoor | -40¬+85 | 5¬100 |
Model Selection Table
Model | Measuring range °C | Accuracy | protection pipe material | specification | Installing Fixtures | |
D | L | |||||
WSS-480 | -80-+40 0-80 0-100 0-150 0-200 0-400 0-500 0-600 | 1.5 | 1Cr18Ni9Ti 304 316 316L Hastelloy C-276 | Φ100 | 75 100 150 200 300 400 500 750 1000 | None |
WSS-580 | Φ150 | |||||
WSS-481 | Φ100 | Movable external thread | ||||
WSS-581 | Φ150 | |||||
WSS-482 | Φ100 | Movable internal thread | ||||
WSS-582 | Φ150 | |||||
WSS-483 | Φ100 | Fixed thread | ||||
WSS-583 | Φ150 | |||||
WSS-484 | Φ100 | Fixed flange | ||||
WSS-584 | Φ150 | |||||
WSS-485 | Φ100 | Bite type thread | ||||
WSS-585 | Φ150 | |||||
WSS-486 | Φ100 | Bite type flange | ||||
WSS-586 | Φ150 |
Application
It is one kind of thermometers to measure middle and low temperature on the spot. It could be used to directly
measure temperature of liquid, vapor and gas ranging from -80 to 500.
Features
1. Directly display temperature on the spot
2. High reliability and long life expectancy
3. Many structure forms to meet different demands
Operation Theory
Bimetallic thermometer is based on bimetal bended into ring shape. One side of bimetal expands in time of
being heated, which results in revolving of indicator, and then the meter will indicates the corresponding
temperature value.
Main Technical Parameters
1 Executive Standard: JB/T8803-1998
2 Nominal Diameter of Dial: 60, 100, 150
3 Accuracy Class: (1.0), 1.5
4 Thermal Response Time: ≤40s
5 Protection Class: IP55
6 Angle-adjusting Error: It shall be no more than 1% of its measuring range
7 Return Error: It shall be no more than the absolute value of basic error limit.
8 Repeat: The repeat range shall be no more than 1/2 of absolute value of basic error limit.
9 Measuring Range