Home  >  Pressure Measuring Instruments  >  Pressure Transmitters

Rosemount Pressure Transmitter 2088(Absolute and gage) - 2088

Rosemount pressure transmitter 2088, Versatile gage or absolute pressure transmitter with unmatched long-term stability - more info check here: http://www.buymeasuringtools.com/Rosemount-Pressure-Transmitter-2088-Absolute-and-gage-10047176/

Quick Brief

Place of Origin: Singapore Brand Name: ROSEMOUNT Model Number: 2088 Manufactured by: ROSEMOUNT Type: Versatile gage or absolute pressure Color: Skyblue Output: 4-20mA Protocol: HART

Product Features:

Rosemount pressure transmitter 2088

Versatile gage or absolute pressure transmitter with unmatched long-term stability

Business Terms:

Port: Xi'an or other Chinese port

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 10000 Piece/Pieces per Month

Payment Terms: L/C,D/P,T/T,Western Union,MoneyGram

Contact Supplier
Rosemount Pressure Transmitter 2088(Absolute and gage)
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Standard rosemount export carton,1 pc into 1 carton

Delivery Detail: 3-4weeks

Specifications and Product Details:

Rosemount Pressure Transmitter 2088

Versatile gage or absolute pressure transmitter with unmatched long-term stability and reliability

Features

  • Manufactured by Rosemount
  • Calibrated spans from 0.3 to 10000 psi
  • Up 0.04% accuracy (optional)
  • Total performance of ±0.15%
  • Installed five-year stability of 0.125%
  • Unmatched Dynamic Performance
  • Optional PlantWeb Functionality to increase plant productivity
  • Responds up to eight times faster than the typical pressure transmitter

Performance Specifications
(Zero-based spans, reference conditions, silicone oil fill, and 316LSST isolating diaphragm.)
Reference Accuracy: ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability
±0.075% of calibrated span (high accuracy option)
Ambient Temperature Effect: Expressed as a total effect per 50 °F (28 °C)

Total effect includes zero and span effects:± (0.15% URL + 0.15% of span) from 40 °F to 185 °F(-40 °C to 85 °C)
Stability: ±0.10% of URL for 12 months
Vibration Effect: Less than ±0.1% of URL when subjected to vibration of: peak constant displacement of 4 mm (515 Hz) and constant acceleration of 2 g (15150 Hz) and 1 g (1502000 Hz).
Power Supply Effect: Less than 0.01% of calibrated span per volt
Mounting Position Effect: Zero shift of up to 1.2 inH2O (0.30 kPa), which can be calibrated out. No span effect.
RFI Effect: Less than ±0.25% of upper range limit from 201000 MHz at 30 V/m with leads in conduit. Less than ±0.25% of upper range limit from 20-1000 MHz at 10 V/m with unshielded twisted pair (no conduit).
Transient Protection Limits
IEEE 587 Category B
6 kV Crest (1.2  50 s)
3 kA Crest (8  20 s)
6 kV Crest (0.5 s by 100 kHz)
IEEE 472
SWC 2.5 kV Crest,1 MHz waveform
General Specifications
Tested to IEC 801-3
Functional Specifications
Service
Liquid, gas, and vapor applications
Ranges
Output
Code S: 420 mA dc
Code N: 1-5 volt dc, low power
(Outputs are directly proportional to the input pressure)
Rangedown
20 to 1
Load Limitations
Reverse polarity protection is standard. Maximum loop resistance is determined by the power supply voltage as described by the following equations:
Max. Loop Resistance = 43.5 (Power Supply Voltage 10.5)
Power Supply
External power supply required. Transmitter operates on
10.536 V dc with no load (612V for Low Power). Reverse
polarity protection is standard.
Current Draw
Output Code N: ≤ 3 mA without LCD display.
Overpressure Limits
Range 1: 120 psig max
All other ranges: two times the URL
Burst Pressure
11,000 psi for all ranges
Zero can be suppressed between atmosphere for gage
transmitters or 0 psia for absolute transmitters and upper range
limit, provided the calibrated span is equal to or greater than the
minimum span, and the upper range value does not exceed the
upper range limit.
Time Response
Time Constant: 200 milliseconds
Dead time: < 0.1 s
Update rate: 20 times per second minimum
Temperature Limits
Process
Silicone fill sensor: 40 to 250 °F (40 to 121 °C)
Inert fill sensor: 22 to 250 °F (30 to 121 °C)
Process temperatures above 185 °F (85 °C) require derating
the ambient limits by a 1.5:1 ratio:
Ambient:
Storage:
50 to 230 °F (46 to 110 °C)
40 to 185 °F (40 to 85 °C) with LCD display
Humidity Limits
0100% relative humidity
Volumetric Displacement
Less than 0.00042 cm3
Turn-on Time
2.0 seconds, no warm-up required
Transmitter Security
Activating the transmitter security function prevents changes to the
transmitter configuration, including local zero and span
adjustments. Security is activated by an internal switch.
Failure Mode
If self-diagnostics detect a sensor or microprocessor failure, the
analog signal is driven either high or low to alert the user. High or
low failure mode is user-selectable with a jumper on the
transmitter. The values to which the transmitter drives its output in
failure mode depend on whether it is factory-configured to
standard or NAMUR-compliant operation. The values for each are
as follows:
Physical Specifications
Electrical Connection
1/214 NPT, M20  1.5 (CM20), PG 13.5, or
G 1/2 female (PF 1/2 female) conduit entry
Process Connection
1/214 NPT female, DIN 16288 G 1/2 male, RC 1/2 female (PT 1/2
female), M20  1.5 (CM20) male
Process Wetted Parts
Isolating Diaphragm
316L stainless steel or Hastelloy C-276
Process Connector
316L stainless steel CF-3M (Cast version of 316L SST,
material per ASTM_A743) or Hastelloy C-276
Non-wetted Parts
Electronics Housing
Low-copper aluminum, NEMA 4X, IP65, IP67,CSA enclosure
Type 4X
Paint
Polyurethane
Cover O-rings
Buna-N
Fill Fluid
Silicone or inert fill
Weight
Output Code S and N: Approximately 2.44 lb (1.11 kg)
Tagging
The transmitter is tagged, at no charge, in accordance with
customer requirements. All tags are stainless steel. The standard
tag is permanently attached to the transmitter. Tag character
height is 1/8 in. (0.318 cm). A wired tag is available upon request.
Accessory Block and Bleed Valve (S5 Option)
The Rosemount 306 Integral Manifold is pre-assembled to
transmitter and leak checked.

Rosemount Pressure Transmitter 2088(Absolute and gage) suppliers    Rosemount Pressure Transmitter 2088(Absolute and gage) manufacturers