Home  >  Pressure Measuring Instruments  >  Pressure Transmitters

Melt pressure transmitter with flange - PT124B-116/116T

Melt pressure transmitter with flange, 1. Internal 80% shunt calibration, 2. Max diaphragm Temperature is 350 - more info check here: http://www.buymeasuringtools.com/Melt-pressure-transmitter-with-flange-10016175/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: ZHYQ Model Number: PT124B-116/116T Pressure range: 0~5MPa~200MPa Output signal: 2mV/V, 3.33mV/V; 0~5V, 0~10V, 4~... Accuracy: 0.5%FS; 1.0%FS Power supply: 10VDC; 24VDC Diaphragm temp: 260℃ Thermocouple: J,K,E

Product Features:

Melt pressure transmitter with flange

1. Internal 80% shunt calibration

2. Max diaphragm Temperature is 350

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 3,000 Piece/Pieces per Month

Payment Terms: T/T,Western Union,MoneyGram

Contact Supplier
Melt pressure transmitter with flange
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Standard exporting packing

Delivery Detail: 2 weeks

Specifications and Product Details:

Description:

Melt pressure transmitter with flangePT124B-116/116T Series which is in view of domestic market. PT124B-116T comes with thermocouple, it can measure the pressure and temperature at one point. This series can be used together with PY Series,G Series,N Series intelligent digital pressure iInstrument of ZHYQ or other brand instrumentation. This series can offer exact pressure measuring, zero & full span can be adjustable, amplify signal can be connected with PLC directly. With the advantage of high precision and reliable pressure measuring and good quality. It can be widely used in chemical fibre, plastic extruder and other high pressure and temperature monitoring.

Specification:

Range: 0…5MPa to 0…200MPa

Output: Transducer 2mV/V; 3.33mV/V; Transmitter 0~5V,0~5V,4~20mA

Accuracy: ±0.5%FS, ±1.0%FS

Input voltage: Transducer 10V DC ; Transmitter 24V DC (12~36V DC)

Rigid length: 6″(standard), 9″, 12″ (optional)

Over pressure: 150%FS

Internal shunt calibration: 80%FSO±1%

Insulation resistance: ≥500MΩ

Max Insulation temp: 80°C/180°F

Max diaphragm temp: 230 °C/450 °F ( Special material 535°C/900°F)

Zero shift: ≤0.15, ≤0.3MPa/100°C

Temp type: J,K,E,PT100 Optional(PT124B-112T)

Electric connection: 5PIN,6PIN, direct down-lead

Process connection: 1/2″-20UNF, M14×1.5, M18×1.5(Customer design)