Portable PGas-31 Infrared Gas Leak Detector
1. NDIR principle Sensor.
2. Quantitative detection.
3. Detect CH4,SF6.etc
Port: Zhengzhou
Minimum Order Quantity: 1 Piece/Pieces .
Supply Ability: 10 Piece/Pieces per Week .
Payment Terms: T/T,.
Contact SupplierPackaging Detail: Customary Packing and Oringinal Packing is available
Delivery Detail: 4 weeks
Portable PGas-31 Infrared Gas Detector
Brief introduction
The measurement principle of (NDIR)" Non-dispersive Dual-wavelength Infrared Spectrum" is adopted for PGas-31 gas infrared quantitative detector. There is no radiotive emitter and it is convenient to carry; the screen of hand-held probe uses OLED, it is self-luminous with high brightness, with no visual angle problem; high precision, good stability and sensitivity, and the resolution of leakage detection can reach 1ppm; the response time is fast; with no consumable parts, life time of the sensor is extra long; it can detect gases include C2H2,CH4,C4H10,C2H4,C2H6, C3H8,CO2,CO and SF6, etc.
PGas-31 Infrared Gas Detector
1 Display screen of host machine
2 Host machine
3 Power switch
4 Aviation plug
5 Filter cap
6 Probe rod
7 Probe panel
8 Probe
9 Communication wire
Hand-held probe is embedded with microcontroller, besides the function of gas sampling, detecting and displaying the concentration of gas, the controller also have functions of calibration, alarm value setting and acoustooptic alarm, etc., the operation is simple and the using is convenient. The hand-held probe is connected with the host machine through a cable to transfer the data.
Host machine besides power supply to the hand-held probe, the host machine can also receive the measurement data transmitted from the hand-held probe, so as to perform display and storage, meanwhile, it can also realize the functions of alarm setting, storage mode setting and display mode setting, etc
Main features
Technical parameters
Measurement principle | Infrared (NDIR) |
Measurement range | Refer to lectotype table |
Sampling mode | Pumping type |
Service temperature | -10~60°C |
Power supply | 7.2V DC, internal battery power supply |
Response time (T90s) | 1~5 second(s) |
Warm-up time | 100 seconds |
Probe unit rod length | 22cm |
Service life of sensor | >10 years |
Calibration time | Calibration once every six months |
Alarm mode | Buzzer |
Lectotype table for detected gas (part gas)
Model | Measured gas | Measurement range (volume content) | Measurement precision |
PGas-31-CO2-1 | CO2gas | 0-5000ppm | ±1%F.S. |
PGas-31-CO2-2 | CO2gas | 0-2% | ±1%F.S. |
PGas-31-CO2-3 | CO2gas | 0-20% | ±1%F.S. |
PGas-31-CO2-4 | CO2gas | 0-100% | ±1%F.S. |
PGas-31-CO-1 | CO gas | 0-20000ppm | ±2%F.S. |
PGas-31-CO-2 | CO gas | 0-10% | ±1%F.S. |
PGas-31-SF6 | SF6gas | 0-1000ppm | ±1%F.S. |
PGas-31-CH4-1 | CH4gas (methane) | 0-4.4%(0-100%LEL) | ±1%F.S. |
PGas-31-CH4-2 | CH4gas (methane) | 0-100% | ±1%F.S. |
PGas-31-C2H6 | C2H6gas (ethane) | 0-2.4 %(0-100%LEL) | ±1%F.S. |
PGas-31-C3H8 | C3H8gas (propane) | 0-1.7%(0-100%LEL) | ±1%F.S. |
PGas-31- C4H10 | C4H10gas (butane) | 0-1.4%(0-100%LEL) | ±1%F.S. |
PGas-31- C2H2 | C2H2gas (acetylene) | 0-2.3%(0-100%LEL) | ±1%F.S. |
PGas-31- C2H4 | C2H4gas (ethylene) | 0-2.4%(0-100%LEL) | ±2%F.S. |
Executed standard
GB12358-2006 "Gas monitors and alarms for workplace—General technical requirements"