Fixed Nitrogen Dioxide NO2 Gas Transmitter
Fixed Nitrogen Dioxide NO2 Gas Transmitter
TGas-1031 Series Combustible, Toxic and Harmful Gas transmitter can continuously measure the concentration of site gas, and convert the concentration signal into 4-20mA output. It is extensively applied in petroleum, petrochemistry, chemical industry, gas, coal, metallurgy and electric power; safety detection in municipal administration, telecommunication and traffic tunnel construction; the place where combustible, poisonous and harmful gas might leak, such as gasholder station and special industrial factory building.
Main features
High Accuracy NO2 Nitrogen Dioxide Gas Detector
1.Two kinds of optional mode of power supply
2. High and low concentration alarm
3. High sensitivity gas sensor
4. Automatic modification of ageing curve of sensor
5. Self-reparing.
Parameters | Characteristics |
Detectable gas | Combustible vapour of liquids, including methane, LPG, coal gas and gasoline, etc., as well as poisonous and harmful gas |
Measurement precision | ±5%F.S |
Repeatability | 2% |
Measurement range | Refer to lectotype table for details |
Drift | Zero drift: ±2%F.S Range drift: ±5%F.S |
Response time | <30s(T90) |
Sampling method | Diffusion |
Working environment | Temperature: -30°C to 60°C; humidity: below 85% (no coagulation) |
Remote control mode | By the adjustment mode by infrared remote control, the detector can be adjusted without opening of cover |
4-20mA output | 4-20mA output corresponding to 0-100%, maximum load 800 ohms |
Alarm output | The effective alarm is 1 point or 2 points; each alarm shall use SPDT electronic relay. Contact rating of alarm relay: Ohmic load: 5A@24Vdc or 120Vac or 240Vac Inductive load: 50VA |
Communication | Communication description: two-wire system parallel RS485 protocol, 32 points at most Connection: Twisted pair with shield Distance: maximum 1000m |
Input voltage | 24VDC±25%; power: 2W/way |
Certificate | Explosion-proof grade: ExdIICT5 Protection class: IP66 |
Using cable | ≥2.5mm2×4 Screened cable line, outside diameter of cable is required to be between 6mm- 9mm |