Home  >  Flow Measuring Instruments  >  Flow Meters

Liquid Flow Switch - WFS10

Differential Pressure Switch, 1.Storage temperature: -29-82, 2.Ambient temperature: -20-71, 3.Media temperature range: -20-93 - more info check here: http://www.buymeasuringtools.com/Liquid-Flow-Switch-10000456/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: ACOL Model Number: WFS10 Storage temperature: -29~82: Ambient temperatur...

Product Features:

Differential Pressure Switch

1.Storage temperature: -29-82

2.Ambient temperature: -20-71

3.Media temperature range: -20-93

Business Terms:

Port: Shanghai

Minimum Order Quantity: 100 Piece/Pieces

Supply Ability: 300,000 Piece/Pieces per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
Liquid Flow Switch
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Carton Boxes.

Delivery Detail: about 20 working days

Specifications and Product Details:

Overview:

WFS10 differential pressure flow switch,designed for OEM customers to control flow accurately.It was designed to be a compact,cost-effective differential pressure switch for applications involving hot or cool air,proof-of-flow,filter monitoring etc,It provides an output when a pre-set difference is exceeded.The set point can be easily modified.The value can set by our professional according to customer's requirement and print on the label.

Technical parameters:

Storage temperature: -29°C~82°C

Ambient temperature: -20°C~71°C

Medium temperature range: -20°C-93°C

Pressure connection: 1/4" SAE(7/16" –20UNF)G , 1/4"NPT for optional)

Max. static pressure: 10bar

Max. pressure difference: 5bar

Set point repeatability: ±1%

Output mode: one SPDT dry contact output, one or two for optional

factory set one SPDT dry contact

Switch: 10A(max),125/250VAC

Electrical connection: model DIN 43650 /direct connect(105°C 2×0.75 or 3×0.75mm for optional)

Monitoring and application:

The pressure difference will increase with filtering, switch is on and output a signal when reached the pre-pressure value. If it automatically clean, the signal would be transmitted to controlling disk and then the controlling disk start to clean and open the waste valve. If worker to clean, the warning signal will be supplied.

Pump status and feed back to automatic controlling system:

The pressure difference is stable when the flow is constant, it would be changed when the system resistance is changed. The relation of pressure difference and flow, can refers to the pump performance data. So the differential pressure flow switch used for pump monitoring as well as the minimum flow control. When the actual pressure exceeds the set value, the switch output a dry contact signal for controlling system to indicate the pump has flow. The status light will indicates the pump status if it has.

Heat exchanger flow controlling

The differential pressure flow switch used for flow controlling is one of the most important application in HVAC system. It is the best substitutes of target type differential pressure flow switch. The reset flow is the minimum value used to check whether satisfy the requirement or not. The disconnect flow is protected instrument from decreasing flow. Following we take plate and extension-type heat exchanger, shell and tube type heat exchanger examples to introduce the characteristics of differential pressure flow switch.

Plate and extension-type heat exchanger

Plate heat exchanger with compact size and high heat transmission performance, has been widely used in cooling as evaporator and condenser. It is necessary to prevent plate heat exchanger from frost damage. A great deal of experimentation show that there is a possibility of freezing when the current flow less than the rated flow about 50%, so it is important to keep the current flow not less than 50% of rated flow. The pressure of 50% rated flow is the protection value of plate type heat exchanger, according to this value to choose differential pressure flow switch. We suggested to buy the fixed set point switch to ensure the value is right(the pressure difference can be tested by our professionals)

Shell and tube type heat exchanger

Shell and tube type heat exchanger used in cooling as evaporator and condenser. The

unstable flow directly influence the mainframe., so it is important to control the flow to ensure mainframe work normally. The 70% pressure of rated flow is the lower limit of protection value, we can obtain it according to the pressure and flow curve or measure in scene. You can consult the professionals of the ACOL for specific method. We suggest to buy double set points adjustable differential pressure flow switch, one of them can be used to indicate the heat exchanger cleaning status. Set the reasonable pressure difference and choose the status light, when the waste is overmuch the status light is on to remind the customer to clean heat exchanger. Avoid energy waste because of the heat transfer effect drops and influence main engine work.

Liquid Flow Switch suppliers    Liquid Flow Switch manufacturers