1)Settings with HART-protocol
2)Galvanic isolation
3)2 wire technology
4)Explosion-proof Certification
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 1000 Unit/Units per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: Standard export package
Delivery Detail: within 2 weeks after payment received
Isolation hart temperature head transmitter MS183
Performance
Application area
Technical Characteristics
Programmable...................Use PC or the hand operator
Measuring range....................Set via PC or by the hand operator
Cold junction accuracy.................. ±1°C(TC)
Max-load.................................(V -16V)/0.025A(Current output )
Limit current........................≤25mA
Response time..............1s
Alarm signal.................Underranging linear drop to3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit: ≤3.6mA or ≥21.0mA
Automatic switching while sensor damaged
Temperature drift........0.01% FS/1°C
Long-term stability...........≤0.1°C per year or 0.05 %per year
Electrical connection
Wiring