1,Portable deformation quenching machine
2,Operates simply
3,Connect with computer
4,ISO9950
5,Patent No:ZL 2008 20069148.0
Port: Qingdao,China
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 100 Piece/Pieces per Month
Payment Terms: L/C,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: 75x54x50(cm) with wooden case
Delivery Detail: Deliver within 15 working days after receiving the deposit
KHR Portable Detector for Quenching Medium Performance
1 Patent number:ZL 2008 2 0069148.0
2 Using portable achieved bath of dynamic measurement and control.
3 Direct determination of medium cooling rate, with existing traditional indirect method than the more accurately determine the medium, the cooling performance.
4 Meet the national standards, facilitate to international advanced technology integration.
Product principle
This detector according to international standards IS09950:1995 manufacturing, adopt inside pack thermocouple nickel alloy probe testing medium performance curve test method of cooling. Will probe heated to specified temperature (usually for 850 °C), insert the waiting media cooling, through the internal microcomputer system records probe temperature on time and the cooling speed changes with temperature, and the internal four-color drawing printer will test results drawn by cooling process curve (temperature/time) and cooling characteristic curve (temperature/cold speed), Also can print the result into form output. According to the above results assess medium cooling performance.
Applications
KHR are widely used in laboratory standard condition checking the performance of different media, which is more suitable for the field work environment of cooling bath monitor, is to improve product quality, reduce heat and avoiding waste effective means.
1,For heat treatment plant
1)Test for determining the production parts with a certain kind of liquid cooling groove maximum cold speed minimum and maximum of 300°C, as bath monitoring criteria;
2)Cooling bath site regularly monitor,
3)Cooling medium restocked acceptance.
4)Judge cooling bath should replace or to preparation,
5)Quenching quality accident (quenching cracks, deformation, not quench) analysis,
6)Monitoring cooling bath different parts and stir intensity under different cooling characteristics and to optimize the cooling process and equipment;
2,Cooling medium manufacturers used to
1)Product quality monitoring.
2)Analysis medium composition and characteristics of the relationship, determine the cooling medium composition, Develop new products;
Main Technical specifications
Probe | Furnace | Measurement record device | ||||
Probe ontology size | 12.5× 60mm | Furnace type | Vertical tubular furnace | Sampling speed | Max1000 times/S | |
Heating temperature | <900°C | Measurable max cold speed | 2000°C/S | |||
Probe length | 600mm | Heating time | <10min | LCD touch screen size | 8 feet | |
Temperature-control accuracy | ±1°C | |||||
power supply | AC220V 50Hz,50W | |||||
Probe thermocouple | 1.5mm WRNK | power supply | AC220V,50Hz 1000W | |||
Outline dimensions | 310×210×320mm | Outline dimensions | 290×250 ×130mm |
Operation scene