Digital Insulation Resistance Meters
Digital Insulation Resistance Tester
Insulation Megohm Meters
Insulation Megohmeter
CE
Port: Shenzhen
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 100000 Piece/Pieces per Month
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: Carton box for outer, gift box for unit
Delivery Detail: 5 ~ 30 days
Digital Insulation Resistance Meters.
Digital Insulation Ressistance Tester.
Digital Insulation Megohm Multimeter.
• Complies with IEC/EN 61010-1 1000V CAT III ,600 V CAT IV.
• 1000V DC Voltage,750V AC Voltage.
• Max display: 6600
• Auto/Manual Range
• MAX/MIN/Average/Relative value measurement
• Battery voltage detector/Low battery indication/ Auto Power off
• Overload protective voltage : 600V.
• Batteries:Four AA batteries (NEDA 15A or IEC LR6) Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries
• Standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
• Insulation Measurement Range : 0.01 MΩ ~ 2 GΩ.
• Insulation Test Voltages : 50V/100V/250V/ 500V/1000 V .
• Insulation Source Voltage: + 20 %, - 0 %.
• Insulation Short-Circuit Test Current : 1 .5mA nominal.
• Insulation Auto Discharge : Discharge time <1 second for C = 1 μF or less.
• Insulation Live Circuit Detection : Inhibit test if terminal voltage > 20 V prior to initialization of test.
• Insulation Maximum Capacitive Load: Operable with up to 1 μF load.
• Storage Temperature : -40 °C ~ 60 °C.
• Operating Temperature: 0°C ~ 40 °C .
• Storage Altitude: 12000m
• Operating Altitude: 2000m 1000V CAT III,3000m 1000V II
• Temperature Coefficient: 0.05 × (specified accuracy) per °C for temperatures < 18 °C or > 28 °C.
• Relative Humidity: 40%~75%.
• Dimension: 205*102*58mm.
• Weight: 390g.
Technical Specification:
Measurement Function | Range | Resolution | Accuracy |
DC Voltage | 600mV | 0.1mV | ±(0.5% rdg +5) |
6V | 1mV | ||
60V | 10mV | ||
600V | 100mV | ||
1000V | 1V | ||
AC Voltage | 600mV | 0.1mV | ±(1.5% rdg+30) |
6V | 1mV | ||
60V | 10mV | ||
600V | 100mV | ||
1000V | 1V | ||
DC Current | 60mA | 0.01mA | ±(1% rdg+5) |
400mA | 0.1mA | ||
AC Current | 60mA | 0.01mA | ±(1.5% rdg+3) |
400mA | 0.1mA | ||
Resistance | 600Ω | 0.1Ω | ±(1.2% rdg+5) |
6KΩ | 1Ω | ||
60KΩ | 10Ω | ||
600KΩ | 100Ω | ||
6MΩ | 1kΩ | ±(2.0% rdg+20) | |
60 MΩ | 10kΩ | ||
Capacitance | 6nF | 0.01 | |
60nF | 0.1n | ±(5%+20) | |
600nF | 1n | ||
6μF | 10n | ||
60μF | 100n | ||
600μF | 1μ | ||
6mF | 10μ | ||
60mF | 100μ | ||
Frequency | 660.0Hz | 0.1Hz | ±(1.5% + 5) |
6.600kHz | 1Hz | ||
66.00kHz | 10Hz | ||
>10kHz | |||
Temperature | 1300°C | 1°C | ±(1%+2) |
Insulation Resistance Measurement:
OutputVoltage | Display Range | Resolution | Test Current | Resistance Accuracy |
50V(0~20%) | 0~5MΩ | 0.01 MΩ | 1mA.50K | ±(3%+5) |
5~50MΩ | 0.1 MΩ | |||
100V(0~20%) | 0~5MΩ | 0.01 MΩ | 1mA.100K | ±(3%+5) |
5~50MΩ | 0.1 MΩ | |||
50~100MΩ | 1MΩ | |||
250V(0~20%) | 0~25MΩ | 0.1 MΩ | 1mA.250K | ±(3%+5) |
25~250MΩ | 1MΩ | |||
500V(0~20%) | 0~50MΩ | 0.1 MΩ | 1mA.500K | ±(3%+5) |
50~500MΩ | 1MΩ | |||
1000V(0~20%) | 0~5MΩ | 0.1 MΩ | 1mA.1000K | ±(3%+5) |
5~500MΩ | 1 MΩ | |||
0.5G~2.0MΩ | 0.1GΩ | ±(5%+5) |
Accessories:
Test Leads, Clips, K Type Thermocouple, Multifunction socket, battery, operational manual.
Warranty: one year
Contact: Ms. Elinor
Mobile: 86-13699890579
Skype: elinor201012