water meter, chemical meter, meter, electromagnetic flowmeter
Port: shanghai or ningbo
Minimum Order Quantity: 1 Unit/Units
Payment Terms: T/T
Contact SupplierPackaging Detail: Carton
Delivery Detail: 7-10days
water meter, chemical meter, meter, electromagnetic flowmeter
Suitable tube caliber: DN15~DN2600(below DN25 unstandard)
Electrode material: 316L(stainless steel), HC, HB, Ti, Ta
Suitable Medium: Liquid with conductive ratio more than 5 μs/cm
Measuring range: 0.1~10m/s (extendable to 15m/s)
Upper limit of span: 0.5~10m/s. 1~5m/s recommended
Accuracy class: 0.3, 0.5, 1.0
Output signal: 4~20mADC, load≤ 750Ω, 0~3kHz, 5V with source and changeable width. High terminal and effective frequency output, RS485 interface
Operation pressure: 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (special)
Fluid temperature: 20C~80C, 80C~130C, 130C~180C according to liner material
Environmental temperature: sensor40~80º C. Transducer 15~50º C
Environmental humidity: ≤85%RH (at 20º C)
Cable outlet size: M20x1.5
Power supply: 220VAC± 10%, 50Hz± 1Hz, 24VDC± 10%
Power consumption: ≤8W
Protection ratings Combined type: IP65. Separate type: Sensor IP68, transducer IP65
Materials of liner: PTFE, soft rubber etc
Connection of flange: GB911988(DIN2051, BS4504)
Earthing material: 1Cr18Ni9Ti (stainless steel), HC, Ti, Ta, Cu