wall mounted ultrasonic flowmeter
Different version UFM can support Chinese or
English display, easy to operate
Port: SHANGHAI
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 1000 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: cartons
Delivery Detail: in 3-5 working days
wall mounted clamp-on ultrasonic water flow meter / wall mounted Ultrasonic Flowmeter / AFV-600A / ultrasonic water flow meter /
FEATURES
High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%,
Accuracy: better than ±1%
Wide Measuring Range
Several types transducer for selection, measuring pipe
size from DN15mm to DN6000mm
Chinese or English menu
Different version UFM can support Chinese or
English display, easy to operate
High Reliability
Adopt low voltage, multi-pulse technology to
improve accuracy, useful life and reliability
Strong Anti-interference
Dual-balance signal differential receiver/driver circuit to
avoid interference of converter, TV tower, high voltage line etc.
Powerful Recording Function
Automatically record the following data: 1. The totalizer data of the last 512 days/128 months/5 years 2. The time and corresponding flow meter of the last 64 times of power on and off events 3. The working status of the last 32 days
SEPECIFICATION
Optional Transducers | Model | Measuring Range | Liquid Temperature | Accuracy | |
Clamp-on | S-1(small size) | AFVS1 | DN15-100mm | -30C°∼90C° | Better than ±1% |
M-1(medium size) | AFVM1 | DN50-1000mm | |||
L-1(large size) | AFVL1 | DN300-6000mm | |||
High-tem clamp-on | HT-1(small size) | AFVHT1 | DN15-100mm | -30C°∼160C° | |
HT-2(medium size) | AFVHT2 | DN50-1000mm | |||
Insertion | IS-1(standard) | AFVIS1 | DN80-6000mm | -40C°∼90C° | |
IS-2(lengthen) | AFVIS2 | ||||
Prove section | Prover section | AFVPS | DN15-1000mm | -40C°∼90C° | Better than ±0.5% |
Power Supply | AC220V or DC24V | ||||
Input | 3 channel 4-20mA analog input | ||||
Output | Isolation RS-232/RS-485 output, 2 channel isolation OCT output: 1 channel isolation 4-20mA output (two-wire system) | ||||
Communication Protocols | Compatible with METER-BUS, MODBUS, Fuji extended protocol and general water meter protocol. |