-Multi-jet, dry-dial, easy for maintenance;
--Magnetic drive reliable characteristic, long working life;
--Vacuum sealed regis
Port: lianyungang,qingdao,shanghai
Minimum Order Quantity: 100 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month
Payment Terms: L/C,T/T,T/T+L/C
Contact Supplier
Working condition:
Water temperature: 0.1°C~40°C for cold water meter .
Water pressure : ≤1.0Mpa
Maximum permissible error:
(1) in the lower zone from qmininclusive up to but excluding qtis ±5%.
(2) in the upper zone from qtinclusive up to and including qsis ±2%;
Type | Size (mm) | Class | qs Overload Flow | qp Permanent Flow | qt Transitional Flow | qmin Minimum Flow | Minimum Reading | Maximum Reading |
m3/h | L/h | m3 | ||||||
LXSG-15 | 15 | B | 3 | 1.5 | 120 | 30 | 0.00005 | 99,999 |
LXSG-20 | 20 | B | 5 | 2.5 | 200 | 50 | 0.00005 | 99,999 |
Type | Size | L Length | B Width | H Height | d Connecting Thread |
mm | |||||
LXSG-15 | 15 | 165 | 104 | 121 | G3/4B |
LXSG-20 | 20 | 195 | 104 | 121 | G1B |