can equiped with remote transmission and caculator.
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 500 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: WOODEN CASE
Delivery Detail: IN A MONTH
Liquid turbine flowmeter technique feature
Regarding to the high viscosity hydraulic oil, machine oil, small caliber may adopt practice flow demarcation.
Norm. press. DN (mm) | Flow rate(m3/h) | Fluid temp. () | Norm. Press. PN (Mpa) | Environ. Temp. () | Relative Humidity (%) | Max. Press. Loss (MPa) | |||||
Basic error ±0.2% | Basic error ±0.5% | Basic error ±1% | |||||||||
Lower limit | Upper limit | Lower limit | Upper limit | Lower limit | Upper limit | ||||||
2A | 0.03 | 0.15 | -20~120 | 6.3 16 25 40 | -25~ +55 | ≤80 | 0.15 | ||||
4A | 0.04 | 0.25 | 0.12 | ||||||||
6A | 0.1 | 0.6 | 0.08 | ||||||||
10A | 0.2 | 1.2 | 0.05 | ||||||||
15A | 0.6 | 4 | 0.6 | 6 | 0.035 | ||||||
25A | 1.6 | 10 | 1 | 10 | |||||||
40A | 3 | 20 | 2 | 20 | 2.5 | 0.025 | |||||
40B | 2 | 20 | 2 | 20 | |||||||
50A | 6 | 40 | 4 | 40 | |||||||
50B | 4 | 40 | 4 | 40 | |||||||
80A | 16 | 100 | 10 | 100 | |||||||
80B | 10 | 100 | 10 | 100 | |||||||
100A | 25 | 160 | 20 | 200 | 1.6 Or 2.5 | ||||||
100B | 20 | 200 | 20 | 200 | |||||||
150A | 50 | 300 | 40 | 400 | |||||||
150B | 44 | 400 | 40 | 400 | |||||||
200A | 100 | 600 | 80 | 800 | |||||||
250A | 160 | 1000 | 120 | 1200 | 1.6 | ||||||
300A | 260 | 1600 | 180 | 1800 |