Home  >  Temperature Instruments

temperature recorder controller - C18P

Programmable Temperature Controller, Up to 50 segments, RS-485 available, high accuracy: +/-0.2%, heat and cool control - more info check here: http://www.buymeasuringtools.com/temperature-recorder-controller-10079912/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: Tcontroller Model Number: C18P Usage: Industrial Theory: Temperature Controller programe: 50 segments certificate: CE color: black input type: Unversial input

Product Features:

Programmable Temperature Controller

Up to 50 segments, RS-485 available

high accuracy: +/-0.2%

heat and cool control

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 10000 Piece/Pieces per Month 1

Payment Terms: T/T

Contact Supplier
temperature recorder controller
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: box

Delivery Detail: 1day

Specifications and Product Details:

temperature recorder controller

ProgrammableTemperatureController
1)90~260VAC power supply
2)Up to 50 segments, RS-485 available
3)SV Re-transmission

4)high accuracy: +/-0.2%
5)heat and cool control

Details photo of temperature controller:

Features:
Programmable Control Function of 30 Segments,
Any amplitude of the slope can be set for temperature
High flexibility in program and operation. It has programmable/maneuverable commands such as
Jump (loop). Run, Hold and stoP.
Good performance without overshoot and undershoot
4 power-off/power-on event handling modes selectable.

Specification's for temperature controller:
Input type: (Either of below specifications can be used selectively in the same instrument)
Thermocouple: K, S, E, R, J, T, B, N.
Resistance temperature Detector: PT100, Cu50.
DC Voltage: 0_5V, 1_5V, 0_1V, 0_100mV, 0_20mV, etc.
DC current (external shunt resist needed): 0_10mA, 1_20mA, 4_20mA, etc.
Optional: Apart from the above-mentioned Input type, additional type can be provided upon request.
Instrument Input range
K(-50--+1300C), S(-50--+1700C), R(-50--+1650C), T(-200--+350C),
E(0_ 800C), J(0--1000C), B(0--1800C), N(0_ 1300C).
PT100(-200--+600C), Cu50(-50--+150C).
Linear Input: -1999--+9999 defined by user.
Measurement accuracy
0.2%FS: RTD, linear voltage, linear current and input with ice point compensation or Cu50 copper
Compensation.
0.2%FS± 0.2C: Thermocouple input with internal automatic compensation.
Response time ≤ 0.5s ( when dL=0).
Note: For thermocouple B, the measurement accuracy of plusmn; 0.2% FS can be guaranteed when input
Range is between 600--1800C, and not guaranteed when input range is between 0--600C.
Control mode:
On-off control mode (deadband adjustable)
Intelligence control, including fuzzy logic PID control and advanced control algorithm with
The function of parameter auto tuning (MPT).
Output mode (modular)
Relay contact discrete output (NO+NC): 264VAC/1A or 30VDC/1A
BCR NO contact discrete output (NO+NC): 85_ 264VAC/0.2A (continuous), 2A (20mS
Instantaneous, repeat period≥ 5s)
SSR Voltage output: 12VDC/30mA (used to drive SSR).
Linear current output: 0_ 10mA, 4_ 20mA (Output voltage greater than 11V)
BCR cross zero trigger o .

3.Parameter Setting Flow Chart:

Program Setup Flow Chart: