Temperature controller have advance microcontroller and firmware design,improved noise immunity.Simple and accurate Self Tuning
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Month 1
Payment Terms: T/T
Contact SupplierPackaging Detail: box
Delivery Detail: 1day
Differential Temperature Controller - C18
1.1 Main feature.
1.2 Model definition.
Advanced modular hardware design is utilized for Temperature Controller series instrument. The instrument with enhanced lateral plate can be equipped with maximum modules of 5.There are more than ten kinds of modules, some of which are double-duty module. Modules of special function can be customized on request.
The basal Temperature Controller instrument has provided many functions enough to meet different requirements asked by users. In order to expand its application bound, an optional software function is provided. The options make the instrument to be able to meet some users' special requirement. There is another manual about these options for those users with special requirement.
The type number of Temperature Controller series instrument is made up of 10 parts, for example:
It shows that the basal function of this instrument is C18 type, front panel dimension is 96×96mm, main output is linear current output without isolation, alarm 1 is relay contact output module, alarm 2 is not installed in, a RS485 communication interface with photoelectric isolation is installed. It is equipped with enhanced lateral plate, auxiliary output is relay contact output module. Optional input type (F2 radiation type pyrometer) and No.3 software function are also available
2. TECHNICAL SPECIFICATION OF TEMPERATURE CONTROLLER.
Input type: (Either of below specifications can be used selectively in the same instrument)
Thermocouple: K, S, E, R, J, T, B, N
Resistance temperature Detector: Pt100, Cu50
DC Voltage: 0~5V, 1~5V, 0~1V, 0~100mV, 0~20mV, etc.
DC current (external shunt resist needed): 0~10mA, 1~20mA, 4~20mA, etc.
Optional: apart from the above-mentioned Input type, additional type can be provided upon request. (Graduation index is needed).
Instrument Input range.
K(-50--+1300°C), S(-50--+1700°C), R(-50--+1650°C), T(-200--+350°C),
E(0~800°C), J(0--1000°C), B(0--1800°C), N(0~1300°C).
Pt100(-200--+600°C), Cu50(-50--+150°C)
Linear Input: -1999--+9999 defined by user.
Measurement accuracy.
0.2%FS: RTD, linear voltage, linear current and input with ice point compensation or Cu50 copper compensation.
0.2%FS±0.2°C: thermocouple input with internal automatic compensation.
0.5%FS: T only
response time ≤0.5s ( when dL=0).
Note: for thermocouple B, the measurement accuracy of ±0.2% FS can be guaranteed when input
range is between 600--1800°C,and not guaranteed when input range is between 0--600°C.
Control mode:
On-off control mode (deadband adjustable)
Tcontroller artificial intelligence control, including fuzzy logic PID control and advanced control algorithm with the function of parameter auto tuning (MPT).
Output mode (modular)
Relay contact discrete output (NO+NC): 264VAC/1A or 30VDC/1A.
BCR NO contact discrete output (NO+NC): 85~264VAC/0.2A (continuous), 2A (20mS
instantaneous, repeat period≥5s)
SSR Voltage output: 12VDC/30mA (used to drive SSR).
Linear current output: 0~10mA, 4~20mA (Output voltage greater than 11V)
BCR cross zero trigger output: can trigger TRIAC of 5~500A, two parallel-connected BCR or BCR power module.
Alarm function: upper limit, low limit, positive deviation and negative deviation, selectable using parameters.
Alarm output: 2 modular output.
Manual function: AUTO/MAN bumpless transfer(C18 series only )
Power supply voltage rating: 85-264VAC/50-60Hz.
Power consumption: ≤5W.
Ambient temperature: 0~50°C.
Front panel dimension: 96X96mm, 160X80mm, 80X160mm, 48X96mm, 96X48mm
Panel cutout dimension: 92X92mm, 152X76mm, 76X152mm, 45X92mm, 92X45mm.
Parameter Setting Flow Chart:
Program Setup Flow chart:
4.FRONT PANEL AND OPERATION:
Details photo of temperature controller: