spectrophotometer instrument(AA500F) - AA500F

1.Spectrophotometer Instrument(AA500F), 2.Fully Automated,Advanced Graphite Furnace,Flame Analysis., 3.Optic System Auto Change - more info check here: http://www.buymeasuringtools.com/spectrophotometer-instrument-AA500F-10302500/

Quick Brief

Place of Origin: China (Mainland) Brand Name: A & E Lab Model Number: AA500F Size: 1280x745x7400mm Weight: 160kg Wavelength Range: 190nm-900nm Measurement Range: 0.1nm,02nm,0.4nm,1.0nm

Product Features:

1.Spectrophotometer Instrument(AA500F)

2.Fully Automated,Advanced Graphite Furnace,Flame Analysis.

3.Optic System Auto Change

Business Terms:

Port: Guangzhou, Shanghai, Beijing

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 100 Set/Sets per Week

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Contact Supplier
spectrophotometer instrument(AA500F)
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Standard Export Packing.

Delivery Detail: Within 10-15days after received payment.

Specifications and Product Details:

A & E Lab.

Main Products: Atomic Absorption Spectrometer (AAS), Fluorescence Spectrophotometer, Bio-Spectrophotometer, UV Vis Spectrophotometer, Visible Spectrophotometer, Flame Photometer, Whiteness Meter, Turbidity Meter, Colorimeter, Gloss Meter, Tintometer, Automatic Polarimeter, Auto Melting Point Apparatus, Automatic Refractometer, Abbe Refractometer, PH/DDS/TDS Meter, etc.

Features:

Fully Automated

² The flame and graphite furnace is integrated into one instruments.The change over from one technique to

another is carried out by simple key strokes within the software.

² The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and

optimization of each hollow cathode lamp by the software.

² The spectral bandwidth is automated and is available with choice of five slit sizes.

Advanced Graphite Furnace

² Horizontally heated platform graphite tube.The unique design of graphite furnace reduces the chemical

interference effects and memory effects by uniformly heating the graphite electrode.

² The computer controlled heating program all.Iows the users to select the best heating program for analysis.

² The optical temperature during the atomization stage ensures the rapid heating and rapid analysis.This helps

to extend the life of graphite tube and enhance the analytical accuracy.

Flame Analysis

Sensitivity(Cu): 2.0μg/ml Absorption>0.2 Abs

Detection(Cu): Cu<0.0004μg/ml(flame);Cd<0.4×10-12g(graphite furnace)

Cu<0.7%(Air-Acetylene Analysis);

Ba<1% (Nitrous Oxide Analysis)

Cu<2%,Cd<2%(Graphite Furnace Analysis)

Background Correction: Deuterium Lamp>×40,Self Reversal>×60

Character Concentration:

<0.02μg/ml1%(Cu);<0.15mg/ml1%(Nitrous Oxide-Acetylene,Ba)

Character Value: Cu<0.3×10-10g,Cd<0.3×10-12g

Burner Head: Titanium Alloy Burner

Nebulizer: High-Efficiency Glass Nebulizer

Atomization Chamber: Corrosion-Resistant Material

Position Adjustment: Automatic Changeover of Flame and Furnace

Automatic setting of Optimum Height for Flame Burner

Safety Functions: Burner identification,Flame Sensor,Gas leak sensor,

Low gas pressure sensor,power loss protection,gas loss flame protection

ModelAE-AA500F

Optic System

Wavelength Range190nm-900nm
MonochromatorCzemy-Turner Configuration
Spectral Bandwidth0.1nm,02nm,0.4nm,1.0nm,

2.0nm (5steps,Automatic Changeover)

Wavelength Accuracy±0.15nm
Wavelength Repeatability<0.05nm
Resolution<30% or 0.2nm ±0.02nm
Baseline Stability0.005A/30min
spectrophotometer instrument(AA500F) suppliers    spectrophotometer instrument(AA500F) manufacturers