RK - 220 SERIES rack monitor
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATIONS: | |||||||
Input | 4 to 20mA output from Oxygen / Toxic / Combustible 2/3 Wire Gas Transmitters | ||||||
Range | -99 to 999 programmable by user, reads % L.E.L.,%L.F.L., P.P.M. OR % VOL. | ||||||
Resolution | 0.01, 0.1, 1 programmable by user | ||||||
Accuracy | ± 0.5 % of the full scale value | ||||||
No. of Input cards | Max. 16 module cards (Optional available 24 nos. and 48 nos. depends upon panel size ) | ||||||
Display | 1)3 Digits of 8mm (Height) Red L.E.D display for Gas Concentration 2) 20 segment Red color Bar Graph Display for Gas Concentration 100% Full scale, 5% Per step L.E.D | ||||||
LED Indication | 8 No, AL1, AL2, AL3, Health Check / Failsafe Indication, PRG, CAL, Optional TX for Transmitting signal & RX for Receiving signal. | ||||||
Set point | 3 Independent Alarm set point programmable by user AL1, AL2, AL3 | ||||||
Control action | LO / HI, HI / LO, LO/ Very LO, HI-Very HI, Programmable by user AL1, AL2, AL3 | ||||||
Hysteresis | 0 to 10 counts, Individual setting for AL1,AL2 & AL3 programmable by user | ||||||
Relay Output | 4 NO, 1 NO/C/NC relay contact rated 230VAC / 5A for AL1, AL2, AL3 and Failsafe Relay | ||||||
Relay Latching | Programmable Latch / Non-Latch facility for AL1, AL2 & AL3 | ||||||
Setting | Setting by 4 keys on front panel 'Set/Next'‚'Up'‚'Down'‚'Test / Ack' | ||||||
Monitoring | i) By Display : Sensor Break / Open shows 'oPn'‚Under range shows 'Und' & Over range shows ‚'our' ii) By Current O/P : Upscale current >21mA, Down scale current < 1mA, selectable | ||||||
Supply Voltage | 18 to 36 VDC, 24 VDC normal for module card OR 230V AC ± 10% for wall mounted panel | ||||||
Cable | 1.5 sq. mm 3 Core OR 2 Core, Flexible OR Armored shielded cable from Gas transmitter to Monitor | ||||||
Operating Temperature | 0 to 50°C± 5%, Relative Humidity: Below 95% non Condensing | ||||||
Cabinet Material | Aluminum housing with powder coating | ||||||
Terminal | 20 connectors with 1.5 Sq. mm. Wire connection facility for each channel on back side of panel | ||||||
Mounting | Panel mounting / Wall mounting | ||||||
DETAILS | No. Of Channels | Dimension in mm (Approx) | Cutout Size in mm (Approx) | Weight in Kg | |||
( W ) | (H) | (D) | (W) | (H) | (Approx) | ||
2 Channel Rack | 118 | 134 | 200 | 63 | 134 | 1.0 | |
4 Channel Rack | 157 | 134 | 200 | 113 | 134 | 2.5 | |
8 Channel Rack | 260 | 134 | 200 | 215 | 134 | 4.0 | |
16 Channel Rack | 484 | 134 | 200 | 439 | 134 | 7.5 | |
Complete Gas Detection Panel | 575 | 357 | 425 | --- | ----- | 15.0 | |
Optional | a)Isolated RS-485 Serial port with MODBUS RTU Protocol output for PC interface b) Isolated 4-20mA retransmission output for PLC, DCS, any recorder c) 4 NO, Open Collector O/P rated 100mA at 32VDC instead of 4 NO Relay d) SMARTLOG / SCADA SOFTWARE for online graph & data report for safety Audit or real time graph, history data, alarm report e) Flame Proof or Non Flame Proof Industrial Hooter, Hooter cum Flasher, Chart recorder, Cables, PC Software, Gas Transmitters, 24 VDC power supply, Gas calibration kit. |