pressure transducer
1)Housing can be rotated through 330
2)Range: -0.1~ 70MPa
3)Supply voltage :10.5...45 VDC
Port: shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month
Payment Terms: T/T
Contact SupplierPackaging Detail: standered package
Delivery Detail: 1-2weeks after payment received
pressure transducer
Technical data:
* Supply voltage:12...45 VDC
* 2-wire-system :4...20 mA with superimposed signal for HART protocol digital communication
* 3-wire-system (optional):1...5V
* Signal range:3.8mA.....22.8mA
* Signal on alarm:3.8mA/ 22.8mA/Others on request
* Accuracy :Nominal range 0.1%
0.25% accuracy for range trundown 4:1
0.5% accuracy for range trundown 10:1
* Power supply effect:Negligible
* Vibration effect : <0.01% of URL /g when tested 200Hz in any axis relative
* Thermal effec :±0.05%/10K
* Compensated temperature range of sensor:-20...80°C
* Permissible load:≤50(V-12)Ω
* Stability:0.1% FSO/Year
* Switch on delay :5s
* Damping :0 to 100s, step: 0.1s
* Response time:200 ms (without consideration of electronic damping)
* Self stability configuration :0 to 2%
* Filter configured:0 to 160 uA
* Communication resistance for HART Protocol:Typ. 250 Ω