1.paper cup stiffness testing machine
2.easy to operate
3.accuracy Indication error 0.1%
4.high quality
5.3 years warranty
Port: Yantian
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 300 Set/Sets per Month
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: By standard export wooden case.
Delivery Detail: Within 15 working days when recieve 30% downpayment.
paper cup stiffness testing machine
Equipment Overview:
The paper cup stiffness test bench is fully automatic electronic test equipment, easy to use, test range, applicable to a variety of capacities cup body stiffness measurements, is the ideal cup cup body stiffness measurements. Also,it is the specific instruments for the paper cup body stiffness detection.
Main Features:
Mechanical cup cup body stiffness requirements in accordance with principles of design. The instrument contact forward and backward with the number of motor drive, cup body resistance force sensor, all the movements control, data, measurement and calculation of processing by the MCU to complete by the liquid crystal display, printer, printing test report. The instrument is fully automatic electronic test equipment, the use of special convenience, the test range, applicable to a variety of capacities cup body stiffness measurements, is the ideal cup cup body stiffness testing instruments.
To meet the criteria:
The paper cup stiffness testing machine according to QB / T 2294-2006 "cups", GB2679 • 3 "Cardboard Stiffness Determination of the" standard of the instrument's basic requirements and JJG157-1995 "Non-metallic tension, pressure, and universal testing machine" General technical requirements for the design .
Applicable Industry:
It is the necessary physical propertied testing equipment for a paper cup manufacturing plant and associated research, also, is the ideal measuring cup body stiffness.
Technical parameter:
Model | HZ-6010 paper cup stiffness testing machine |
Measurement range | 1~10N |
Indication resolution | 0.01N |
Indication accuracy | Indication error 0.1%,indication changes≤1% |
Testing speed | (12.5±1.2)mm/min |
The relative movement of the distance probe | (9.5±0.2)mm |
Measuring head-to-neutral | ≤0.2mm |
Distance of two probe | (40~120)mm |
Outside dimension | 500mm×270mm×340mm(L*W*H) |
Temperature | 20 Degree/ temperature ±10 Degree/Temperature |
Power | 220V±10%;50Hz,Reliable power supply should be grounded |
Protection | Force of more than full-scale, the contacts automatically return |
Note | The working environment clean,withour strong magnetic filed and vibration source. |