Home  >  Temperature Instruments

microcomputer digital temperature controller with defrosting function JC-501 - JC-501

digital temperature controller, 1.Defrost function, 2.Automatic temperature control, 3.Refrigeration applicate - more info check here: http://www.buymeasuringtools.com/microcomputer-digital-temperature-controller-with-defrosting-function-JC-501-10213018/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: juchuang Model Number: JC-501 Usage: temperature controller Theory: Temperature Controller

Product Features:

digital temperature controller

1.Defrost function

2.Automatic temperature control

3.Refrigeration applicate

Business Terms:

Port: Zhongshan

Minimum Order Quantity: 500 Unit/Units

Supply Ability: 5000 Unit/Units per Month

Payment Terms: T/T,Western Union

Contact Supplier
microcomputer digital temperature controller with defrosting function JC-501
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: 80pcs per boxGross weight: 25kgs

Delivery Detail: 10 -15 days

Specifications and Product Details:

temperature controller
·Temperature display (Celsius/Fahrenheit degrees)
·Temperature control
·Manual, automatic defrost by turning off
·The cold-room sensor temperature can lock during defrost
·Parameter sets and value storing
·Compressor re-start delay
·Parameter locking
·The factory default resumption
·Offset on sensor temperature
·Self testing
·Power supply: 220V/AC~240V/AC50/60Hz or 110V/AC~120V/AC60Hz
·Power consumpotion: less than 5W
·Output relay for compressor: N.O. 30A/250V 50/60Hz.
·Temperature sensor: NTC,1 sensor for Room-temp. display
·Resolution1
·Accuracy±1 or ±2
·Range of temperature control: -45 ~ 45
·Panel dimension: 78×35×76mm
·Mounting hole dimension: 71×29mm
Parameter
Function
Set range
Default
PA
Menu password
00 ~ 99
00
E1
Lower set point limit
-45 ~ Set temperature
-20
-40 ~ Set temperature
-05
E2
Higher set point limit
Set temperature ~ 45
20
Set temperature ~ 120
68
E3
Temperature hysteresis
01 ~ 10
05
01 ~ 36
07
E4
Comp. Start delay time
00 ~ 10Min
00
E5
Offset on room temp.
-05 ~ 05/
00
F1
Max. Defrost duration
01 ~ 60 Min
20
F2
Defrost interval time
00 ~ 24Hr
06
F4
Display during defrost
00=Normal display
00
01=Last value before defrost
C1
Temperature unit
00=
00
01=
CPA
Changing menu password
00 99Setting00, the menu password is cancelled
00