lpg gas mass flow meter/fuel oil mass flowmeter - RV-100CMFI

1.Temperature accuracy+-1, 2.Output of current loop 4mA-20mA, 3.Output of frequency/pulse0Hz-10kHz, 4.Delivery time 5days - more info check here: http://www.buymeasuringtools.com/lpg-gas-mass-flow-meter-fuel-oil-mass-flowmeter-10227047/

Quick Brief

Place of Origin: Liaoning China (Mainland) Brand Name: zerogo Model Number: RV-100CMFI Accuracy grade: ±0.2% Temperature range: -60℃ -- +200℃ Atmospheric pressure range: 86kPa--106kPa Caliber: DN1-150

Product Features:

1.Temperature accuracy+-1

2.Output of current loop 4mA-20mA

3.Output of frequency/pulse0Hz-10kHz

4.Delivery time 5days

Business Terms:

Port: DALIAN

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 1000 Set/Sets per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
lpg gas mass flow meter/fuel oil mass flowmeter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: protect boxes

Delivery Detail: 5days

Specifications and Product Details:

TECHNICAL SPECIFICATION

Products specs are divided to eleven based on nominal line sizes: DN1, DN3, DN6, DN10, DN15, DN25, DN40, DN50, DN80, DN100, DN150 (units: mm).

Configurations

Figure 1 Sensors (primary meter)

Figure 2 Essential Safety Transmitter Figure 3 Composite Transmitter and Sensor

Every meter consists of two parts: the sensor (primary meter) and the transmitter (secondary meter).

The sensor (primary meter) is machinery part of mass flow meter. There are a vibrator, two displacement sensors and a temperature sensor in it.

The transmitter (secondary meter) is display part of the meter, also is electrical part. There are power supply, analog circuits, digital circuits, displayer, and output circuits and so on in it. Its foundational functions are receiving and regulating the electrical signal from sensors, directly getting mass flow, temperature and density after regulating, and calculating volume flow and other need parameters from known parameters. It can display, output, store and long distance transmit, and you can modify the parameters of flow meter. There is a diode safety barrier in transmitters; the function of the diode safety barrier is safeguard to isolating explosion.

As the composite explosion-proof flow meter, the sensor (primary meter) is essential safety; the transmitter (secondary meter) is explosion isolated. The sensor and the transmitter may all operate under hazardous area.

TitlesTechnical Specifications
Mass flow accuracy±[0.2% +(zero stability /flow rate×100%)]
Mass flow repeatability±(1/2) ×[0.2% +(zero stability /flow rate×100%)]
Density range0.2 g/cm3~3.5g/cm3
Density accuracy±0.002g/cm3
Temperature range-60°C~+200°C
Temperature accuracy±1°C
Output of current loop4mA~20mA
Output of frequency/pulse0Hz~10kHz
Contactor capacity of a Batch Control relay24V/0.1A
Contactor formnormal open
TitlesSpecifications
Temperature range of fluid-40°C~+200°C
Environmental temperature range0°C~+40°C
Environmental humidity<90% RH, non condensation
Atmospheric pressure range86kPa~106kPa
Power supply of transmittersEssential safety Voltage: AC(220±10%)V,(50±5%)Hz

Composite Voltage: DC (24±10%) V

Power consumed<15W

Installation of meters

The mass flow meter mostly is divided to two parts: a sensor (primary meter) and a transmitter (secondary meter), a shield cable connects two parts. The transmitter (secondary meter) of the essential safety flow meter must mount in safety area according to prescriptive conditions (see section 3.2). A sensor and a transmitter of the essential safety flow meter installation show in Figure 4.

Figure 4 Sketch of Essential Safety Flow Meter Installation