hot water flow meters
high temperature proof
good accuracy and qunlity
high reliability and durability
Port: Xiamen port
Minimum Order Quantity: 1 Piece/Pieces 2 pieces
Supply Ability: 10000 Piece/Pieces per Year 8000 pcs
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: 1 piece/carton box
Delivery Detail: 15 days after purchase order
hot water flow meter
Flanged pipeline type
Nominal inside diameter | Pressure≤4.0 | 11.0≥Pressure≥5.0 | Remark | |||
Total width | Total height | Total width | center high | |||
L | H | L | H1 | |||
DN15 | 170 | 345 | 200 | 300 | The dimensions above are for reference,ex-factory product shall prevail | |
DN20 | 350 | |||||
DN25 | 355 | |||||
DN32 | 380 | |||||
DN40 | 190 | 390 | 220 | 310 | ||
DN50 | 400 | |||||
DN65 | 220 | 415 | 250 | 320 | ||
DN80 | 425 | 325 | ||||
DN100 | 240 | 445 | 260 | 325 | ||
DN125 | 260 | 460 | 280 | 350 | ||
DN150 | 280 | 515 | 300 | 365 | ||
DN200 | 300 | 580 | 320 | 390 | ||
DN250 | 360 | 450 | Determined by the factory | |||
DN300 | 400 | 480 | ||||
Note :Pressure≥15Mpa the housing width determined by ex-factory |
Functional characteristics:
1, Measurement flow of liquid, gas, steam, ropy mediums or ambulatory mediums in low, normal or
high temperature condition.
2,Total quantity measurement accuracy is not less than 0.2%.
3,High sensitivity, able to measure very low velocity below 0.8m/s.
4,No movable part, safe and reliable.
5,Wide measure range, bigger than 1:30.
6,Good repeatability, generally 0.1~0.08% , fast to measure.
7,Small pressure loss, only about 1/2P of Standard Hole Board.
8,Able to adopt hang weight method to test the flow meter.
9,Measurement range can be changed by replacing target according to need.
10 ,LCD display.
11,4-20mA, 0-10V, impulse, and RS485 outputs.
12,Easy installation and maintain.
13,anti-interfere, anti-impurity, anti-acid, corrosion resistant, portability
Technical data:
Nominal Diameter:6-4000mm
Nominal pressure:-0.1+70MPa
Temperature:-196°(low temperature type)-40°~ +70°(normal temperature),-40°~ +250°(wide temperature type),-40°~ +450°(high temperature),-40—+700°(Extreme temperature type)
Accuracy:gas ±0.5% ±1.0% ±1.5% ,steam ± 0.5% ±1.0% ±1.5% ,liquid ±0.2% ±0.5 % ±1.5%
Measuring range: gas 1:100,1:50,1:30,1:10 steam 1:30,1:20,1:10 liquid 1:200,1:100;1:50,1:30,1:10
Minimum flow:gas:12L/h steam:2kg/h liquid:2L/h Viscosity liquid:12L/h
material:Carbon Steel,304,316(can offer according to customer's need)
Power supply:Built-in 3.6N li batter,(lifetime 1~2 years),external power supply of 24VDC
Output forms:4-20mA;pulse,0-10V;RS232/RS485;Hart protocol,GPS.
Our digital flow meter are all LCD display,it also can show accumulated flow and instant flow
installation:easy to operate and install,easy maintenance
Good repeatability normally 0.1~0.08% and fast measurement
Small pressure loss,only about 1/2ΔP of standard orifice.
Explosion-proof sign: Intrinsically safe type(ExiallCT4);Explosion isolating type(ExdllCT4)
Execution standard:Q/QZRX001-2007
SBLdigital flow meter can widely used a variety of size pipeline and a variety of measurement media