gas detector

Designed for automatic continuous monitoring of concentrations of combustible gases( Methane- Propane) and Carbon Monoxide - more info check here: http://www.buymeasuringtools.com/gas-detector-10166571/

Quick Brief

Place of Origin: Russian Federation Brand Name: AVUS- COMBI white: wire-wireless

Product Features:

Designed for automatic continuous monitoring of concentrations of combustible gases( Methane- Propane) and Carbon Monoxide

Business Terms:

Port: St. Petersburg

Minimum Order Quantity: 1000 Unit/Units

Supply Ability: 5000 Unit/Units per Month

Payment Terms: T/T

Contact Supplier
gas detector
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: cart boxes

Delivery Detail: 2 weeks

Specifications and Product Details:

GAS DETECTORS AVUS-COMBI
TU 4215-007-07518266-2009

1.Purpose: Gas detector AVUS-Combi is designed for automatic continuous monitoring of the combustible gases concentration (methane and propane) and carbon monoxide in dwellings and public facilities in order to detect the excess of permissible concentrations and the timely adoption of effective measures to reduce gas contamination.
Designed in accordance with GOST R EN 50194-2008 and “Technical Regulation Draft on Safety Requirements to Gas Equipment in the Houses”.
"AVUS-COMBI" is a powerful home gas detector based on a modular design, provides the operating abilities of AVUS-M with additional functions:

2. Function:

- self-test function;

- uninterruptible power supply;

-alarm signal for excessive ambient temperature;

-wired and wireless interaction with the gas detectors and an external data system;

-processing and display of information;


3. Competitive advantages:

-. reliability, easy to operate;
-. low power consumption;
-. long term of service;
-. low sensitivity to changes in climatic conditions, including relative humidity;
-. standard performance, modular construction ;
-. safe supply 12 V
-. high selectivity to the detected gas;
-. self-test function of the performance

4. Technical Characteristics:

ParameterGas detector Avus Comby
Measured gasMethane, Propane, Carbon Monoxide
Range of measurement

0 – 50 % LEL Methane, Propane,

0 – 300 mg/m3Carbon Monoxide

The range of permissible absolute error

(from +15 up to +25 °C; 30%-70% relative humidity)

Methane, Propane± 2,5 % LEL

Carbon Monoxide: ± 5 mg/m3for the first threshold

± 20 mg/m3for the second threshold

The range of permissible absolute error (from -10 up to +40 °C; 30%-90% relative humidity)Methane, Propane:± 4 % LEL

Carbon Monoxide: ± 11 mg/m3for the first threshold ;

± 45 mg/m3for the second threshold

Two threshold alarms

7% and15% LEL (Methane, Propane)

20 and 100 mg/m3(Carbon Monoxide)

Sensor typeSemiconductor(Carbon Monoxide,Methane, Propane)
Electrochemical (Carbon Monoxide)
AlarmLED, Sound

Resistance to external factors:
1. Temperatures
2. Relative Humidity
3. Pressure

from -10 up to +40 °C

from 30 to 90 % at T= 25°C

from 84 to106,7 kPa

Power supply from PSU220 V, 50 Hz
Power supply from circuit adapter12 V
Power consumption, not more2 W
Error-free running time, not less20000 hours
Average service life, not less5 years
DimensionsØ 100 mm, h = 50 mm
Weight, not more0,25 kg

5.Competitive consumer characteristics:
Comparing specifications : low power consumption, resistance to climatic factors, long error-free running time, short response time at the target gas presence, good metrological characteristics.
Comparing functionality:
1. Reliability, easy to operate
2. Standard performance, modular construction
3. Long time of service
4. Function self-test performance
Comparing the compliance with other standards:
1. GOST R 50194-2008 and EN standards EN 50194, EN 50291.
2. “Technical Regulation Draft on Safety Requirements to Gas Equipment in the Houses” in the Russian Federation

3. Federal Law dated 30.12.2009 N 384-FZ "Technical Regulations

To Ensure the Safety of Buildings, Facilities and Structures”.
Article 30.”Security requirements for the users of buildings, facilities and structures”.
Point 11. Project documentation must provide the measures preventing the cases of accidents and injury to people caused by explosions, including measures preventing excessive accumulation of hazardous substances in the air of facilities including the application of gas monitoring

gas detector suppliers    gas detector manufacturers