Home  >  Analyzers  >  Gas Analyzers

exhaust gas analyzer--SV-2Q withi factory price - SV-2Q

exhaust gas analyzer--SV-2Q, measure HC, CO gas of automobile, easy to use with factory price - more info check here: http://www.buymeasuringtools.com/exhaust-gas-analyzer-SV-2Q-withi-factory-price-10194625/

Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: cnreliable Model Number: SV-2Q type: automobile emission gas analyzer voltage: 220V power: 50W measure gas: HC, CO color: white weight: 25kg warranty: one year quality warranty after sales service: all life time maintenance

Product Features:

exhaust gas analyzer--SV-2Q

measure HC, CO gas of automobile

easy to use with factory price

Business Terms:

Port: shenzhen

Minimum Order Quantity: 1 Set/Sets full in set

Supply Ability: 500 Set/Sets per Week negotiable

Payment Terms: T/T,Western Union,Paypal

Contact Supplier
exhaust gas analyzer--SV-2Q withi factory price
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: normal package

Delivery Detail: within 2-3 days after your kindly payment

Specifications and Product Details:

exhaust gas analyzer--SV-2Q
SV-2Q Full-Automatic Exhaust Gas Analyzer, in accordance with non-light-disguising infrared absorption method, via micro-computer analysis, directly measure the thickness of HC, CO in the exhaust gas of vehicles .The analyzer introduces advanced foreign technology. It is composed of complete imported machinery cores, boasts the advantages of accuracy measurement, high endurance and speed. It's utilized for auto-manufacturing factories, vehicle inspection stations and garages.
The main technical parameters:
1. Measurement range:
CO:0-10.0 10-2(%)
HC:0-10000 10-6(ppm)
2. Repeatability:≤+-2%
3. Zero floating:
CO: +-0.06 10-2(%)/1h
HC: +-30 10-6(ppm)/1h
4. Not exceed the allowed value for indication error(1 hour)
5. indicated error:
CO:+-10%(relative error0-10%)
HC:+-3(relative error0-2000ppm)
+-5%(relative error2001-5000ppm)
+-10%(relative error5001-10000ppm)
6. Environmental temperature :
temperature:0°C~40°C
humidity:≤80%
air pressure:60~105kPa
power :AC 220V+-10%;50Hz
7. Preheat time:10min
8. Sampling method:directly sampling