Home  >  Analyzers  >  Gas Analyzers

emission analyzer SV-5Q/emission/eanalyzer - SV-5Q

SV-5Q automobile exhaustemission analyzer, used to measure the concentration of HC, CO, CO2, O2, NO - more info check here: http://www.buymeasuringtools.com/emission-analyzer-SV-5Q-emission-eanalyzer-10332133/

Quick Brief

Place of Origin: Tianjin China (Mainland) Brand Name: shengwei Model Number: SV-5Q

Product Features:

SV-5Q automobile exhaustemission analyzer, used to measure the concentration of HC, CO, CO2, O2, NO

Business Terms:

Port: tianjin

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 100 Set/Sets per Month

Payment Terms: L/C,T/T,Western Union

Contact Supplier
emission analyzer SV-5Q/emission/eanalyzer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: carton box

Delivery Detail: within 3 days

Specifications and Product Details:

SV-5Q automobile exhaust emission Analyzer,

In accordance with non-light-disguising infrared absorption method. The main technical parameters

1. Environmental temperature

Temperature-5-40 humidity: 95% Air pressure:70.0-106kPa Power: AC 220V±10%;50Hz± 1Hz

2.Measuremnt scopeHC: 0-1000010-6ppmvol CO: 0-10.0 10-2(%)vol

CO2: 0-20.0 10-2 (%) volO20-25.0 10-2(%)volrotate speed0-10000rpm

NO: 0-5000 10-6ppmvoloil temperature0-120

3.Sampling methodtail gas: sampling directly .The length of sampling tube: 5m,the length of probe:900mm.

Oil temperatureinserting the head of thermo scope into the staff gauge of engine lubricant, the length of which is the same as that of oil staff gauge; blocking with rubber plug to plug up engine oil from ejecting: length of lead: 5m.

Rated rpm Non-contact measurement method. Less than 20cm to the petrol high-voltage flexible cord, measuring petrol rotate speed.

4.preheat time10mins

5.resolutionCO 0.01%volHC: 1ppmvolnormal hexane equivalent CO2: 0.01%volO2: 0.01%vol

NO: 1ppmvol rate speed 1rpm oil temperature 0.1

6.indicated errorCO±0.06% vol or±5% relative error. HC: ±12ppm vol or ±5% relative error

CO2: ±0.5% vol or ±5% relative error O2: 0.1% vol or±5% relative error

NO±25ppm vol or±5% relative error rate speed ±10rpm(0-10000rpm) ±1% measured value (>10000rpm)

7.Stabilityafter preheating, zero excursion and measurement distance excursion in 4 hours should not be over the allowance value of sample value error

8.Repetitiveness: ≤1/2 of absolute of the allowed sample value error

9.Output signal: Number volume: RS232 serial massage exit .

emission analyzer SV-5Q/emission/eanalyzer suppliers    emission analyzer SV-5Q/emission/eanalyzer manufacturers