Home  >  Electronic Measuring Instruments  >  Industrial Metal Detectors

calibration block V1/50 - V1/50

calibration block V1/50, I.I.W Calibration Standard, Material: steel and others, high quality, ultrasonic flaw detector use - more info check here: http://www.buymeasuringtools.com/calibration-block-V1-50-10179021/

Quick Brief

Place of Origin: Beijing China (Mainland) Brand Name: HUATEC Model Number: V1/50 Brand: HUATEC Material: steel and others

Product Features:

calibration block V1/50

I.I.W Calibration Standard

Material: steel and others

high quality

ultrasonic flaw detector use

Business Terms:

Port: Beijing

Minimum Order Quantity: 1 Unit/Units

Supply Ability: 5000 Unit/Units per Month

Payment Terms: T/T,Western Union,Paypal

Contact Supplier
calibration block V1/50
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: gift carton

Delivery Detail: have stock

Specifications and Product Details:

calibration block V1/50

Order CodeTypeDescription
/Application
Standard Made ToMaterial Size
V1A2
(BS)
I.I.W Calibration Standard. Calibration of Shear and compression wave probes. Checking beam angle, emergent point and resolution. Calibration of time base and gain settings.B.S. 2704
DIN 54120
IIW (International Institute of Welding)
Steel

25x100x300mm

V1/50A2
(BS)
Generally as V1. Thicker block minimises side wall echoes.BS 2704Steel

50x100x300mm

V2
(Specify hole diameter)
A4
(BS)
Small calibration block for site checking of shear wave probes, time base and gain. 1.5mm or 5mm diameter hole targetBS 2704
IOW (Institute of Welding)
Steel

12.5x43x75mm

V2/20
(Specify hole diameter)
A4
(BS)
Generally as V2. Thicker block eliminates side wall echoes. 1.5mm or 5mm diameter hole target.BS 2704Steel

20x43x75mm

BCBA5
(BS)
Beam Calibration Block. Beam profile and resolution checks for shear wave probes. Sensitivity checks for shear and compression probes. 9 off 1.5mm holes.BS 2704Steel

50x75x305mm

A6A6
(BS)
Evaluating dominant frequency, pulse, length, dead zone and resolving power for shear and compression probes as BS4331 part 3,1974.BS 2704Steel

25x50x150mm

RTBA7
(BS)
Checking shear wave probe resolution as BS4331 part 3, 1974. Steps of 2,3,4 and 5mm.BS 2704Steel

74mm radius
75mm thick

LSWSPECIALLadder step wedge for timebase calibration with thickness measuring compression probes. 8 steps from 1mm to 8mm.Tolerance of +0.000mm-
-0.040mm
Steel

8x15x120mm

LSW/MSPECIALGenerally as LSW with 15mm diameter steel inserts mounted in plastic. 8 steps from 1mm to 8mm.Tolerance of +0.000mm-
-0.040mm
Steel inserts
Plastic body

10x20x140mm

CSWSPECIALCurved Step wedge for timebase calibration of thickness measuring probes. 5 steps - 2,4,6,8 and 10mm.Tolerance of +0.000mm-
-0.040mm
Steel

100mm long
x 30mm I.D.
Quadrant

MUSPECIALMetric Universal Block for general purpose checking as V1 block.Tolerance of 0.1mmSteel

20x50x150mm

TBR 2 125 (3)SPECIALRadiused test block for calibration of boiler probes. 3 off 1.5mm holes.Tolerance of 0.004 inchSteel

20x25x165mm

TBR 2 125 (5)SPECIALAs TBR 2 125(3) - supplied with 5 off 1.5mm holesTolerance of 0.004 inchSteel

20x25x165mm

A5 Blank Type BESIDetermination of signal curve and beam characteristics of single crystal probes (longer range). 1.6mm diameter hole.ESI 98-7Steel

50x75x305mm

A5 Blank Type CESIDetermination of signal curve and beam characteristics of single crystal probes (longer range). 1.6mm diameter hole.ESI 98-7Steel

50x75x305mm

ESI-BCB
N-A5
ESIChecking twin crystal probes for sensitivity. Contains four additional 1.5mm diameter holes to A5 block.ESI 98-2Steel

50x75x305mm

50 RADESIChecking pulse shape of shear wave probes.ESI 98-2 and
ESI 98-8
Steel

50x75x150mm

ASME
(Specify Thickness)
ASMESetting sensitivity levels for weld testing. Sizes and locations of flaws are dependent on weld thickness.ASME Article 5 Fig T-546.1Steel

Size dependent on weld thickness

ASME/M
(Specify Thickness)
SPECIAL
(ASME)
Metric equivalent of ASME block.Tolerance of 0.1mmSteel

Size dependent on weld thickness

DAC
(Specify Thickness)
SPECIALSetting DAC characteristics for shear wave and compression wave probes. Flaws typically 1.5mm diameter holes at 20%, 40%, 60% and 80% of thickness.Tolerance of 0.0004 inchSteel

Size dependent on product thickness.

calibration block V1/50 suppliers    calibration block V1/50 manufacturers