an automatic transformer multi-parameter measurement instrument TH2818XB free shippig - TH2818XB

TH2818XB meter is an automatic transformer multi-parameter measurement instrument . - more info check here: http://www.buymeasuringtools.com/an-automatic-transformer-multi-parameter-measurement-instrument-TH2818XB-free-shippig-10158695/

Quick Brief

Place of Origin: Jiangsu China (Mainland) Brand Name: TONGHUI Model Number: TH2818XB Display Type: Digital Only Size: 430*185*437mm Weight: 13kg

Product Features:

TH2818XB meter is an automatic transformer multi-parameter measurement instrument .

Business Terms:

Port: Shenzhne

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 100 Piece/Pieces per Day

Payment Terms: T/T,MoneyGram

Contact Supplier
an automatic transformer multi-parameter measurement instrument TH2818XB free shippig
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Specifications and Product Details:

TH2818XB meter -------- an automatic transformer multi-parameter measurement instrument--------FREE SHIPPING

TH2818XB meter is an automatic transformer multi-parameter measurement instrument used for quality control of electronic transformer over a wide range of frequency (20 Hz to 300 kHz).

Almost all low-voltage transformer parameters can be scanned. The primary parameters include Inductance L, Leakage Inductance Lk, Turns-Ratio Tr, DC resistance DCR, Impedance |Z|, and Capacitance (between windings) C etc.;

The secondary parameters include Quality Factor Q , ESR and Phase etc., Pin short can also be detected. The advanced digital sampling technique and high-speed scanning test fixture make the transformer inspection more accurate and efficient, which used to be of low efficiency before such a system was used.

The system provides several signal output impedances for selection in order to be compatible with some well-known LCR instrument providers when an inductor is measured. Turns-ratio is calculated by the inductance of primary and secondary windings, which decreases the measurement error caused by large leakage of magnetic flux, for example low-coupling coefficient transformer.

100mA bias source (option) is selected to perform DC bias measurement for network transformer, filter, etc. at as 2 times speed as other instruments. And the measurement result can be compatible with that of Agilent 4284A.

an automatic transformer multi-parameter measurement instrument TH2818XB free shippig suppliers    an automatic transformer multi-parameter measurement instrument TH2818XB free shippig manufacturers