ZYC03 Counter - ZYC03

Counter, 1. DIN48*24mm panel, 2. Internal Li battery, no external power required., 3. 6 or 8 bits LCD display, 4. Panel mounting - more info check here: http://www.buymeasuringtools.com/ZYC03-Counter-10076984/

Quick Brief

Place of Origin: Shanghai China (Mainland) Brand Name: TOONE Model Number: ZYC03 size: small display: LCD

Product Features:

Counter

1. DIN48*24mm panel

2. Internal Li battery, no external power required.

3. 6 or 8 bits LCD display

4. Panel mounting

Business Terms:

Port: Shanghai

Minimum Order Quantity: 100 Piece/Pieces negotiation

Supply Ability: 30,000 Unit/Units per Month or more

Payment Terms: L/C,T/T,Western Union

Contact Supplier
ZYC03 Counter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: standard exporting packing

Delivery Detail: in stock

Specifications and Product Details:

ZYC03 Counter

I. Description

1. DIN48*24mm standard panel, 50*60mm extension available

2. Internal Li battery, no external power required.

3. 6 or 8 digitals LCD display, big and clear display

4. Panel reset with lock, avoid error operate

5. Input contact or electrical signal, reliable and exact count

6. Top count rate is 200Hz.

7. No mechanical abrasion, long life time, to replace the electromagnetism counter

II. Specification

Power: internal power

Battery life: appr. 5 year (25)

Count range: 0999999/99999999

Minimum count signal: ZYC03-L 100ms (5Hz)

ZYC03-VL/ZYC03-AL 50ms (10 Hz)

ZYC03-H 5ms (100 Hz)

ZYC03-VH 2.5ms (200 Hz)

Reset: panel button reset/ external terminal reset

Operating temperature: -1040 (no freeze)

Humidity: 3585%RH

No voltage input:

Max connect resistance: ≤10KΩ (count ON)

Min disconnect resistance: ≥1000KΩ (count OFF)

Voltage input: H valid

(1) LDC02V HDC430V

(2) L≤5%Ue HAC220V/110V(85%-110%)

Min reset pulse: ≥0.5s

Weight: appr.60g

Installation dimension: 22.5×45mm

III. Cautions

1. The signal and the reset switch or circuit of the counter should close up the connect terminal, make the input wire as short as possible.

2.It is necessary to use shielded cable, avoid inter-twisting with other cable, such as power supply cable or dynamical cable.

3. Reset signal should not connect too long; avoid wasting the internal battery.

4. Contact input should be reliable, avoid to error count caused by contact bounce.

5. It has Lithium battery inside, don’t press it or heat over100 centigrade, avoid Lithium battery to break or burn.