H2 Dew Point Meter
1.High Precision and good stability
2.can analyse the moisture of the gas
3.equipped with build-in printe
Port: Zhengzhou
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10 Unit/Units per Week
Payment Terms: T/T
Contact SupplierPackaging Detail: Customary Packing and Oringinal Packing is available
Delivery Detail: 4 week
H2 dew point Meter1.The dew point transmitter of the analyzer with high performance of Finland Vaisala Company is adopted as the core measurement unit of the entire system,
2.it integrates multiple up-to-date research achievement and proprietary technology in measurement of dew point,
3. it is equipped with precision sampling system for sample gas and intelligent digital processing display,
4.and it is one of existing dew point measurement instruments with the most advanced technique and the most powerful function.
Main features
1.Self-calibrating of zero point and slope at starting up (proprietary technology)
2.Calibration of dew point with full-scale range by single-point method (proprietary technology)
3.Sensor drying protection device (proprietary technology)
4.Operation and control by color touch screen
5.Real-time curve display
6.Storage and printing of measurement data
7.Intelligent prompting of electricity quantity, automatic calibration for slope of intelligent charging protection (proprietary technology
Technical parameters
Measurement of dew point | -80~+20°C, when the dew point temperature is lower than 0°C, the sensor output is frost-point. | |
Typical precision | superior than ±1°c | |
Response time (Td) | when the gas temperature is 20°c | |
-60→-20°c | 5s (63%), 10s (90%) | |
20→-60°c | 45s (63%), 10min (90%) | |
Digital output | RS232 USB2.0 | |
Printing | 24 characters/row, wire-pin printer | |
Working flow | no influence on flow | |
Power supply | built-in lithium battery (8000mAh), AC/DC | |
Charging time | over 6 hours (with intelligent charging protection) | |
Time of usage | >10 hours | |
Operation environment | Ambient temperature | -10~+60°c |
Ambient humidity | 0~100%RH | |
Pressure | 1 atmosphere pressure | |
Dimension | 273mm×257mm×143mm | |
Weight | about 5.6kg |
Legend
1. Real-time curve display
2. Printing of measurement data
3. Storage of measurement data
4. Display of system time
5. Intelligent display of electricity quantity
6. Setting of printing data
7. File storage system
8. Network communication
9. Chinese and English bilingual interface
ZA-3000 series instrument data management system