1.1.0% mass flow rate accuracy
2.Advanced diagnostic function (option)
3.Software download function
Port: China port
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Year
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: in carton
Delivery Detail: 6-7weeks
YOKOGAWA EJX910A Multivariable Transmitter
Introducing the Yokogawa EJX910A multivariable transmitter, a remarkable innovation in multi-sensing technology that makes optimal use of the powerful characteristics of the single-crystal silicon resonant sensor. Experience FlowNavigator (FSA120), PC-based software that is exclusively designed for use with the EJX910A.
Key features include:
*Fully compensated mass flow: all flow factors can be automatically and dynamically calculated to an optimal value
HART protocol type
*Simultaneous dual output of 4 to 20 mA and pulse signals for total flow, flow rate, or alarm status
*HART protocol revision selectable from HART 5 or HART 7
*Long tag supporting up to 32 characters (HART 7)
*Enhanced burst mode and event notification (HART 7)
*SIL2 for safety requirement
EJX910A Multivariable Transmitter | |||||
L Capsule | M Capsule | H Capsule | |||
Range | Differential pressure | -10 to 10 kPa (-40 to 40 inH2O) | -100 to 100 kPa (-400 to 400 inH2O) | -500 to 500 kPa (-2000 to 2000 inH2O) | |
Static pressure | Absolute | 0 to 16 MPa abs (0 to 2300 psia) | 0 to 25 MPa abs (0 to 3600 psia) | ||
Gauge | -0.1 to 16 MPa (-14.5 to 2300 psig) | -0.1 to 25 MPa (-14.5 to 3600 psig) | |||
External temperature | -200 to 800 deg C (-328 to 1472 deg F) | ||||
Span | Differential pressure | 0.1 to 10 kPa (0.4 to 40 inH2O) | 0.5 to 100 kPa (2 to 400 inH2O) | 2.5 to 500 kPa (10 to 2000 inH2O) | |
Static pressure | Absolute/ Gauge | 1 to 16 MPa (145 to 2300 psi) | 1 to 25 MPa (145 to 3600 psi) | ||
External temperature | 10 to 1050 deg C (18 to 1890 deg F) | ||||
Accuracy | Mass flow | ±1.0% | |||
Differential pressure | ±0.04% | ||||
Static pressure | ±0.1% | ||||
External temperature | ±0.5 deg C (±0.9 deg F) | ||||
Flow calculation reference | Primary device | Orifice | Orifice Corner Taps [ISO5167-1 1991] | ||
Orifice Corner Taps [ISO5167-2 2003] | |||||
Orifice Corner Taps [ASME MFC-3M 1989] | |||||
Orifice Frange Taps [ISO5167-1 1991] | |||||
Orifice Frange Taps [ISO5167-2 2003] | |||||
Orifice Frange Taps [ASME MFC-3M 1989] | |||||
Orifice Frange Taps [AGA No.3 1992] | |||||
Orifice D and D/2 Taps [ISO5167-1 1991] | |||||
Orifice D and D/2 Taps [ISO5167-2 2003] | |||||
Orifice D and D/2 Taps [ASME MFC-3M 1989] | |||||
Nozzle | ISA1932 nozzle [ISO5167-1 1991/ISO5167-3 2003] | ||||
Long radius nozzle [ISO5167-1 1991/ISO5167-3 2003] | |||||
ASME FLOW NOZZLES [ASME MFC-3M 1989] | |||||
Venturi | Venturi nozzle [ISO5167-1 1991/ISO5167-3 2003] | ||||
Classical Venturi tube "as cast" convergent section [ISO5167-1 1991/ISO5167-4 2003] | |||||
ASME Venturi Tubes With a rought Cast or Fabricated Convergent [ASME MFC-3M 1989] | |||||
Crassical Venturi Tubes With a machined convergent section [ISO5167-1 1991/ISO5167-4 2003] | |||||
ASME Venturi Tubes With a machined convergent section [ASME MFC-3M 1989] | |||||
Classical Venturi tube with a rought-welded sheet- iron convergent section [ISO5167-1 1991/ISO5167-4 2003] | |||||
Density compensation of fluid | General fluid | DIPPR (Physical property database) | |||
Natural gas | AGA No. 8, ISO 12213 | ||||
Steam | IAPWS-IF97 Water and Steam, 1997 | ||||
Manual mode | Flow factors being input manually | ||||
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||||
Certificates | FM, CENELEC ATEX, CSA, IECEx | ||||
Output | [HART protocol type] Dual output of 4 to 20 mA with pulse signals [FOUNDATION fieldbus type] FOUNDATION fieldbus,2-wire system with digital communication | ||||
HART Protocol Revision* | HART protocol revision can be selected from 5 or 7 when ordering. The protocol revision can be changed by user configuration. | ||||
Supply voltage | HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus:9 to 32 V DC | ||||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) -30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | ||||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||||
Maximum working pressure | 16 MPa (2300 psi) | 25 MPa (3600 psi) | |||
Mounting | 2-inch pipe mounting | ||||
Wetted parts material | Capsule | 316L SST (Diaphragm material is Hastelloy C-276) | |||
Cover flange | ASTM CF-8M | ||||
Housing | Cast aluminum alloy | ||||
Flow configuration tool | FlowNavigator Flow Configuration Software (FSA120) |