Digital Thermo-Hygrometer High Accuracy Humidity and Temperature Meter
1) IEC1010 standard
2)4 Digital liquid crystal displa
Port: Shenzhen
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 5000 Piece/Pieces per Month More can be provided according to customers' need
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: carton box for outer,gift box for unit20pcs for one cartoncarton size:54*38*47
Delivery Detail: 5-7days
1)Accord with IEC1010 standard
2)Numerical Display: 4 Digital liquid crystal display
3)Measurement range: Humidity - 0%~100%RH, Temperature - 20°C ~ +60°C, -4°F ~ +140°F
4)Resolution: Humidity -0.1%RH, Temperature -0.1°C, 0.1°F
5)Accuracy: Humidity -±2.5%RH AT 25°C, Temperature -±0.7°C, ±1.4°F
6)Response time: Humidity - 75 SEC. IN SLOWLY MOVING AIR, Temperature - 40 sec. in slowly moving air
7)RS-232 Interface
8)Data hold
9)MAX/MIN value measurement
10)Auto power off
11)Backlight
12)Power requirements: Battery - one 9V battery 006P IR IEC 6F22 OR NEDA 1604
13)AC adapter - 9VDC /30Ma
14)Minimum plug diameter: Φ3.5mm X 1.35mm
15)Dimension:
Meter -> 183 (L) X 74 (W) X 33 (H)mm
Sensor Probe -> 208 (L) X 15 (D)mm
Weight: APPROX. 300g (including battery)
Accuracy is specified for a period of year after calibration and at 18°C to 28°C(64°F to 82°F) with relative humidity to 75%.
3.1 GENERAL SPECIFICATIONS
3.1.1 Numerical Display: 4 digital Liquid Crystal Display.
3.1.2 Measuring method: Dual-slope integration A/D converter
3.1.3 Temperature modulus: < (0.1 x Accuracy) /°C
3.1.4 Response Time: Humidity→ 75 sec. In slowly moving air
Temperature→ 40 sec. in slowly moving air
3.1.5 Signal Output: RS-232 Data Output
3.1.6 Operating Environment: Altitude up→ to 2000 meters.
Humidity→ 0 to 90%RH (non-condensing).
Temperature→ 0°C~50°C, 32°F~122°F (non-condensing).
3.1.7 Storage Environment: Humidity→ 0 to 80%RH (non-condensing)
- 9 -
HUMIDITY TEMPERATURE METER | |
INSTRUCTION MANUAL | SPECIFICATIONS |
Temperature→ -10°C~60°C, 14°F~140°F (non-condensing)
3.1.8 Power Requirements: Battery→ One 9V battery 006p or IEC 6F22 or NEDA1604
AC adapter→ 9VDC /30mA minimum Plug Diameter: Ø 3.5 mm x 1.35mm
3.1.9 Low Battery Indication: ‘’ displayed
3.1.10 Dimension: Meter→ 183(L)x 74(W)x 33(H)mm; 7.2(L)× 2.9(W)x 1.3(H)inch
Sensor Probe→ 208(L)x 15(D)mm; 8.2(L)x 0.6(D)inch
3.1.11 Weight: Approx.330g