Digital multimeter with infrared thermometer measurement YH1028
GENERAL SPECIFICATIONS
3.1.1 The meter is devised with light and sound alarm to prevent test leads misconnection.
3.1.2 Auto range and manual range options are available.
3.1.3 Overrange protection is provided for all ranges.
3.1.4 Maximum voltage between terminals and earth ground: 1000V DC or rms AC
3.1.5 Operating altitude: max. 2000 meters (7000 ft.)
3.1.6 Display: LCD, 3 readings at the same time
3.1.7 Maximum value display: 3999 digits
3.1.8 Polarity indication: automatic; ‘-‘ for negative polarity.
3.1.9 Overrange indication: ‘0L’ or ‘-0L’
3.1.10 Sampling time approx. 0.4 second per sample
3.1.11 Unit indication function and unit.
3.1.12 Auto power off time 30 min.
3.1.13 Specification of resettable fuse F1 500mA/250V
3.1.14 Fuse protection F2 10A/250V (quick acting).
3.1.15 Operating power 1.5V×3 AAA batteries
3.1.16 Battery low indication ‘’ on LCD
3.1.17 Temperature factor < 0.1×Accuracy /°C
3.1.18 Operating temperature 0°C to 40°C(32°F to 104°F)
3.1.19 Storage temperature -10°C to 50°C(10°F to 122°F)
3.1.20 Dimension 195×92×55mm
3.1.21 Weight approximate 400g(including batteries)
3.2 TECHNICAL SPECIFICATIONS
Ambient temperature 23±5°C Relative humidity < 75%
3.2.1 DC Voltage
Range | Resolution | Accuracy |
40mV | 0.01mV | |
400mV | 0.1mV | ± (0.7% of reading + 2 digits) |
4V | 1mV | |
40V | 10mV | |
400V | 100mV | |
1000V | 1V |
- Input Impedance 10MW
- Overload protection
40mV~400mV range 250V DC or rms AC,
4V-1000V ranges 1000V DC or 750V rms AC.
- Max. input voltage 1000V DC or 750V rms AC
NOTE
At small voltage range, unsteady readings will appear before the test leads contact the circuit. This is normal because the meter is highly sensitive. When the test leads contact
he circuit, the true reading will be shown.
3.2.2 AC Voltage
Range | Resolution | Accuracy |
40mV | 0.01mV | |
400mV | 0.1mV | |
4V | 1mV | ± (0.8% of reading + 3 digits) |
40V | 10mV | |
400V | 100mV | |
750V | 1V | ± (1.0% of reading + 3 digits) |
- Input Impedance 10MW
- Overload protection
4V-750V range 1000V DC or rms 750V AC.
- Max. input voltage 1000V DC or rms 750V AC
- Frequency range 40 to 400Hz
- Response average, calibrated in rms of sine wave
3.2.3 DC Current
Range | Resolution | Accuracy |
400mA | 0.1mA | |
4000mA | 1mA | |
40mA | 10mA | ±(1.2% of reading + 3 digits) |
400mA | 100mA | |
4A | 1mA | |
10A | 10mA | ±(2.0% of reading + 10digits) |
- Overload protection
mA,mA ranges resettable fuses F1 500mA/250V
10A range F2 10A/250V fuse (quick acting).
- Max. input current
mA jack(mA ranges) 4mA,
mA jack(mA ranges) 400mA,
10A jack 10A
- voltage drop
400mA ranges 40mV,
4000mA ranges 400mV,
40mA ranges 40mV,
400mA ranges 400mV,
4A range 40mV
10A range 100mV