HANDHELD digital storage oscilloscope, PORTABLE digital storage oscilloscope, digital storage oscilloscope, digital oscilloscope
Port: FOB SHANGHAI
Supply Ability: 10000 Piece/Pieces per Month
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: Carton
Delivery Detail: Within 7-20 working days after receipt of payment
YB40000 Series Handheld Digital Storage Oscillometer
Vertical | YB42005 | YB41005 | |
YB42010 | YB41010 | ||
Channel | CH1 CH2 | ||
Input coupling | AC, DC | ||
Frequency bandwidth | 200MHz | 100MHz | |
Rising time | ≤1.75ns | ≤3.5ns | |
Deviation deflection | 2mV/div~50V/div, 1-2-5, ±3% | ||
Input impedance | 1MΩ(±2%)//16pF(±2 pF) | ||
Max. input voltage | 400V(DC+AC peak) ≤ 400Hz | ||
Vertical accuracy | 3%±1pixel, 2 mV/div ≤ 5%±1 pixel. | ||
Vertical resolution | 8 bits ADC | ||
Common-mode restrain ratio | DC≥20:1 | ||
Display | ±4 div | ||
Open noise | ≤0.4div | ||
Sweep time factor | Rolling 50s/div~100ms/div; real time 50ms/div ~25ns/div; equivalent 10ns/div ~ 1ns/div | ||
Sampling velocity | Real time: YB40005 series :500Msa/s, equivalent 10Gsa/s | ||
YB40010 series: 1Gsa/s, equivalent 25Gsa/s | |||
Horizontal | Time resolution | 40ps | |
Record length | 50k | ||
Storage depth | 250k | ||
Sampling mode | Real time, equivalent, average(2/4/8/64 four devisions can be set), peak value | ||
Horizontal mode | Main time base, main time base+ window expansion(×2, ×5, ×10) | ||
Cursor readout accuracy | ±(1% read ±1 pixel) | ||
Display range | ±5div | ||
Trig | Trig source | CH1, CH2 , external | |
Trig mode | Auto, edge, external, vedio, pulse width | ||
Hi-freq restrain | Attenuate signal higher than 100KHz, trig sensitivity normal at DC ~10KHz | ||
Low-freq restrain | Attenuate signal lower than 10KHz, the sensitivity normal for above 100KHz | ||
Trig level range | ±4div | ||
External trig | Input impedance: 1MΩ(±5%)//20pF(±2 pF) | ||
Bandwidth: 500KHz | |||
Mode: auto, edge | |||
Trig level: ≤200mVp-p | |||
Vedio trig | TV-V: ≥2div TV-H: ≥2div | ||
Memorizer | Memorizer | 5 | |
Output interface | RS-232 | ||
Digital meter | Resolution | 2003-3-4 | |
Imput impedance | 10MΩ(±1%)//15Pf(±2pF) | ||
Voltage measurement | Range:400mV(0.1mV), 4V(0.001V),40V(0.01V), 400v(0.1V) | ||
DC accuracy (Full scale): ±2% | |||
AC accuracy (Full scale): ±(2% readout±3 pixel): freq 50Hz~1KHz | |||
Resistor measurement | Range:400Ω(0.1Ω), 4kΩ(0.001kΩ), 40kΩ(0.01kΩ), 400kΩ(0.1kΩ), 4MΩ(1kΩ), 40MΩ(0.01MΩ) | ||
Accuracy (Full scale): less than 20MΩ ±(2% readout ± 5 pixel) | |||
At 40MΩ ±(5% readout ± 5 pixel) | |||
Current measure | Range: 4mA, 40mA, 4A | ||
Accuracy (Full scale: 40mA, 400mA, 4A(±3% +10 words) | |||
At 4mA, 4A(±5%+20words) | |||
Short circuit measure | Tell resistor<40Ω( beak) | ||
Diod measurement | Max. readout 2V | ||
Screen | Display | 5.7 inch LCD 320×240 lattice, backlight adjustable | |
Waveform zone | Vertical 8div ×25 dots/div, horizontal 10div×25 dots/div | ||
Physical features | Powers supply | AC 100V~240V/45Hz ~ 60Hz | |
Lithium batteries | 7.2V/4A, the workable time around 4 hours. | ||
Size | 64H×169W×254D(mm) | ||
Weight | About 1.8kg |