RH1000 Online monitoring station; online monitoring system; continuous monitoring system
Port: Shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 500 Set/Sets per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: At clients' option
Delivery Detail: According to the quantity
RH1000 Online monitoring station technical specification
(Version for Wind power station)
1) High reliability
2) Accurately and completely data collection.
3) Realize synchronous sampling at any two channels
4) Good scalability
3Main technical parameters
Maximal input Channels | 16 channels for vibration 8 channels for Process information, 2 channels for tacho | |
Maximal output channels | 1 line for relay, dry contact | |
Vibration signal input | ||
Channels | Max.16 Channels, 8,12,16 Optional synchronous sampling at 4 channels, synchronous sampling at any two channels | |
Compatible transducers | Accelerometer, Velocity Pickups, Non-contact Eddy Current Displacement Probes, voltage transducer, 4~20mA | |
Input | ±10V | |
Transducer driver current | 4mA@24V; Constant current source used for ICP model acceleration transducer | |
A/D conversion | 24 bit | |
Input impedance | 220K | |
Physical quantity | Acceleration, velocity, displacement, user-defined | |
Integral | Once integral, twice integral | |
Accelerometer maximum | 80g, 200mm/s, 10mm, Using 100mV/g transducer | |
Fmax Frequency Fmax | 100Hz –10kHz:9 Position (100,200,500,1K,2K,4K,5K,8K,10K) | |
Sampling rate | 256Hz ~25.6kHz; 9 Position (256,512,1024,2560,5120,10240,12800,256000) | |
Dynamic.signal range | 95dB | |
Harmonic distortion | <-70dB,Other distortion and noise will be lower | |
precision | 1%( 0.1dB), 80Hz | |
Lines | 400,800,1600,3200,6400 | |
Time domain sampling | 1024,2048,4096,8192,16384 | |
Window function | Hanning, Rectangle window | |
Averaging type | Linearity, peak hold | |
Averaging times | 1,2,4,8,16,32,64 | |
Process information | ||
Channels | 8, Isolation input | |
Signal range | ±12V or 4~20mA | |
Rotating speed | ||
Channels | 2 | |
Compatible type | TTL, Eddy current, Hall, | |
Triggering level | ±2V~±30Vpp | |
Electric relay output | ||
Channels | 1 | |
Type | SPST, Normally open or close | |
Voltage and current | 250V AC,2A | |
Control terminals | Server | |
Regular index | ||
Communications | 1)Ethernet v2.0. IEEE802.3, TCP/IP, 10/100baseT 2)Wireless network | |
Memory capacity | 256M | |
Dimensions | 360×260×150, metal shell | |
Protection grade | IP65,waterproof, dust proof | |
Temperature range | (-40 ~ 60)°C | |
Humidity | 95% RH without condensate | |
Electromagnetism compatible authentication | ||
Passed the following tests: 1.Electrostatic discharge interference test 2. RFEMS test 3. Electrical fast transient impulses interference test 4. Surging interference test 5. Damped oscillatory wave immunity test 6. power frequency disturbance of magnetic field test 7. Voltage sags, short interruptions and voltage variations immunity test | ||
Anti-explosion options | ||
Anti-explosion indentification | ExibIIAT4 | Monitoring station |
Exd[ib]IIAT4 | Anti-explosion power source |