Home  >  Flow Measuring Instruments  >  Flow Meters

Variable area flowmeter - H250

Variable area flowmeter, Range :DN15---DN300, Measure Liquid,gas,vapor, Flange:DIN,ANSI,HG,GB ;thread, Temperature: -80C---300C - more info check here: http://www.buymeasuringtools.com/Variable-area-flowmeter-10164637/

Quick Brief

Place of Origin: Germany Brand Name: Krohne Model Number: H250 Application range: liquid,gas,vapors Accuracy: 1.0 or 1.6 Pipe range: DN15---DN300 Output: 4-20mA Protocal: Hart

Product Features:

Variable area flowmeter

Range :DN15---DN300

Measure Liquid,gas,vapor

Flange:DIN,ANSI,HG,GB ;thread

Temperature: -80C---300C

Business Terms:

Port: Dalian

Minimum Order Quantity: 1 Set/Sets n/a

Supply Ability: 150 Set/Sets per Month n/a

Payment Terms: L/C,T/T,Western Union,Paypal

Contact Supplier
Variable area flowmeter
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: carton and wooden

Delivery Detail: within 7 days

Specifications and Product Details:

Variablarea flowmeter

Special features

² Rugged all-metal design

² Easy stocking of parts thanks to modular concept

² Complete interchangeability of all components and assemblies

² Linear display

² Adjustable to any fluid through replaceable cam plate

² Shot-stroke design/parts do not project beyond the flanges,no matter what position the float is in

² Electrical or pneumatic remote data transmission system

² Limit switches can be installed

Metering range(100% values) : water (20°C) 6~15000 l/h

Air (0.1013MPa 20°C) 0.05~4000 m3/h

Rangeability : 10:1

Accuracy class : 1.5 (Special version 1.0)

Operating data

Max pressure : DN15~DN50 PN4.0MPa (Special versio 25MPa)

DN80~DN100 PN1.6MPa (Special versio 16MPa)

Temperature of fluid : -80°C~+220°C

Ambient temperature : Max 120°C(Max.60°C if signal output is electrical)

Current output: 4-20mA (Optional)

Viscosity of fluid : DN15: ≤5mPa.s(H15.1~H15.3)

≤30mPa.s(H15.4~H15.9)

DN25: ≤250mPa.s

DN50~DN150:≤300mPa.s

Connection Standard : Flange to DIN2501 or ANSI ,Special Other standards on request

Electaic : M20×1.5,PG11,1/2”NPT

Owerall height : 250mm

Protection category to DIN 40050 : IP65

Explosion Proof : ExiaIICT3~6

ExdIIBT4