Ultrasonic liquid/fuel level meter
1.Power supply voltage:9-36V
2.Degree of the radiator protection: IP67
3.Patent: YES
Port: ShenZhen China
Minimum Order Quantity: 100 Set/Sets
Supply Ability: 5000 Set/Sets per Month
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: carton
Delivery Detail: 3-10 days
Description
Ultrasonic fuel level meter is used for fuel level measurement in vehicle fuel tanks in order to control fuel consumption. The measurements are realized by the ultrasonic radiator installed directly on the external bottom part of the fuel tank and data processing box. The ultrasonic fuel-level meter can measure levels of diesel and petrol or other liquid materials depending on software settings.
Application
Ultrasonic fuel-level meter UZI measures changing level of any liquid (diesel, gasoline, water, liquefied gas, milk etc.) in moving and fixed tanks (vehicles fuel tanks, fuel tank tracks, railway tank cars, industrial tanks and liquid storages).
The measurement is provided through the tank bottom so no damage and drilling of the tank are needed.
The measured data could be:
•saved in the internal memory which capacity is enough for 1 month autonomic work or
•sent via a transceiver such as GPRS modem or GPS/ GPRS tracker in real time.
Using UZI you can get the following important information:
-Fuel level and amount in the tank
-Amount of dispensed fuel
-Fuel consumption rate
-Theft detection
-Operational and statistical reports
Principle of Operation
Receiving the measured data (application 1)
UZI–Ultrasonic fuel-level meter
Transceiver equipment - (not supplied by our Sensor)
Receiving the measured data (application 2)
UZI–Ultrasonic fuel-level meter
UZI reader – a special adapter for connecting to PC (could be bought from our Sensor separately) Transceiver equipment -(not supplied by our Sensor
Technical Characteristics
Power supply voltage | 9...36V |
Power protection up to | 80V |
Measurement range | 18 –800mm(optional up to1000mm) |
Max load current of outputs | 10 mA |
Max current consumption | 80 mA |
Analog interface(0 …1023) | 0,3....9,7 V |
Frequency output interface (U=10V) | 500-1500 Hz |
Quantity of outputs EIA 485 | 1 |
Quantity of outputs EIA 485/2321 | 1 |
Accuracy of fuel level measurement in static | not more 0.5 % |
Accuracy of fuel level measurement in dynamic | not more 3.0 % |
Accuracy of fuel level measurement | not more 3.0 % |
Degree of the radiator protection IP67 | IP67 |
Working temperature | -40...+80°C |
Nonvolatile memory | 2 MB(30 days if record once in 30 sec.) |
Galvanic isolation of the power supply | yes |
Galvanic isolation of the outputs | yes |
Patent | yes |