1. provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids.
2.Easy setup
Port: XIAN
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 10000 Piece/Pieces per Year
Payment Terms: T/T,Western Union
Contact SupplierPackaging Detail: in carton
Delivery Detail: 2*3weeks
US300FM provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids.
The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing and correlation detection method, US300FM provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids. Easy setup with interactive parameter setting. Easy adjustment with no zero-offset transducers
Specifications
US300FM Performance
Fluid | Liquid with turbidity < 10,000 mg/litter, fluid sound velocity 800 to 3,500 m/s) |
Measured values | Volume flow, mass flow (by setting density), flow velocity, sound speed in fluid (when optional wall thickness probe is provided) |
Pipe size | 25 to 6,500 mm |
Pipe material | Carbon steel, stainless steel, gray cast iron, ductile iron, copper, glass, PVC, etc. |
Flow velocity range | 0.01 to 25 m/s |
Fluid temperature range | -30 deg to +130 deg C. (general use) -30 deg to +200 deg C. (high-temperature use) |
Accuracy | 1% to 3% of reading (depends on application) |
Straight pipe run upstream | More than 10 D (depends on the piping conditions) |
Main unit construction
Housing material | Aluminum (powder coated) |
Water/dust proof | IP65 |
Dimensions (HxWxD) | 200 mm x 280 mm x 71 mm |
Weight | Approx. 2.8 kg |
Transducer construction
Case material | Stainless steel SUS316 Ti |
Water/dust proof | IP65 (General purpose), IP67 (Immersible) |
Functions
Calculation of the two flow inputs | Two values from an average (for two path measurement), sum, or difference for channel A and channel B inputs |
Time-programmable measurement | Automatic start and stop of measurement using internal clock. Can be used with data logging or communication function. |
Parameter setting storage | Storage of pipe and fluid parameters (Maximum of 80 different settings) |
Sound velocity measurement | Measurement of the sound velocity in the liquid |