Float level controller
1.Basic type
2.Explosion protection type
3.Vessels type
4.Specific requirement can be made by order
Port: Dalian
Minimum Order Quantity: 1 Unit/Units
Supply Ability: 5000 Unit/Units per Month
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: In carton or wooden case with foam liner
Delivery Detail: 5 working days
Summary:
UQK-71 float level controller is made of sensor and display controller.
Medium measured: water, industrial sewage, petroleum.
Type: the basic type, explosion protection type and the vessels type.
Application:
It is widely used in the industries of petroleum, chemical, medicine, sewage treatment and so on for measuring the liquid in the open or the closed containers.
The main technology parameters
1.Measuring range: ≤6000mm(according to the clients'demand)
2.Measuring error: ≤±5mm
3.The capacity of the reed tubes:
high power:220V.AC.2A
lower power: 220V.AC.0.1A;24V.DC.0.3A
4.Working pressure: ≤2.5MPa
5.Medium parameters
temperature: -20~120°C
density: ≥0.65g/cm3
viscosity: ≤1.25st
6.Environment condition:
temperature: -40~50°C
relative humidity:≤85%
7.Connection way: flange, thread, or supporting board
(1) flange standard DN125,150,PN0.6,1.0,1.6,2.5MPa, HG20592~20635-97(or other standard)
(2) thread standard: M72×4(suitable density≥1.0g/cm3,floating ball out diameterΦ65)
(3) supporting board:150*60mm
8.Material
flange: carbon steel, 1Cr18Ni9Ti,PVC plastic, Four fluorine spraying
floating ball: 1Cr18Ni9Ti,316,Ti,PVC plastic, Four fluorine spraying
pipeline: 1Cr18Ni9Ti,316,PVC plastic, Four fluorine spraying
9.The sensor with explosion protection
mark: dIIBT1-4
protection class: IP65
the relationship between the explosion temperature and medium temperature:
Temperature | T1 | T2 | T3 | T4 |
Medium temperature | 400 | 290 | 190 | 130 |