Quick Brief

Place of Origin: Guangdong China (Mainland) Brand Name: ZLT Model Number: ZLT-HV50 Power: Electronic Usage: Universal Testing Machine color: white material: stainless steel

Product Features:

Conform to UL94,IEC60695-11-4,IEC60695-11-10.Test flames-50W.

Business Terms:

Port: Guangzhou

Minimum Order Quantity: 1 Set/Sets negotiable

Supply Ability: 5 Set/Sets per Month negotiable

Payment Terms: T/T,cash

Contact Supplier
UL94,IEC60695-11-4 Horizontal-Vertical Flame Tester
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: wooden case

Delivery Detail: 2-30days

Specifications and Product Details:

Product details:Model ZLT-HV50: The ZLT Horizontal-Vertical Flame Chamber Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. It screening procedure for comparing the relative burning behaviour specimens made from plastic and other non-metallic materials ,exposed to a flame ignition source of 50W or 500W nominal power. These test methods determine the linear burning rate and the afterflame/afterglow times,as well as the damaged length of specimens.They are applicable to solid and cellular materials that have an apparent density of not less than 250kg/m3,determined in accordance with ISO845.Then do not apply to materials that shrink away from the applied flame without ignitiong;ISO9773 should be used for thin flexible materials. And it's the combustion test device of plastic materials represented by UL-94. It can perform each test of HB, V0 to V2, 5V and VTM, HBF.

Product three type: 50W,500W,50~500W mixed-type test equipment

SPECIFICATIONS

Test Flame50W(burning test for V-0,V-1,V-2 classification)
Burner TubeInternal diameter: 9.5mm±0.3mm, length:100mm±10mm
Burning Angle0°,20°,45°
ThermocoupleType K (Ni/Cr - Ni/Al)
Thermocouple Size O/D0.5 mm
Standard Copper Block5.5mm±0.01mm, weight:1.76g±0.01g before drilling. Cu-ETP
Time for Temperature to IncreaseFrom 100°C±5°C to 700°C±3°C; 44s±2s (preset)
Overall Height18mm~22mm(adjustable)
Gas Supplymethane,min.98% purity
Flowmeter105ml/min±2%
Manometer0KPa to 7.5KPa
Input Power220 V 50 Hz 3A or 115 V 60Hz Optional
Volume Of Chamber>0.75m³, black interior
Outer DimensionsW*D*H=1100mm*550mm*1100mm
Conform to standardUL94,IEC60695-11-4,IEC60695-11-10

Fitted to the base plate are a flame height scale, a level and adjustable feet.

DIGITAL TEMPERATURE DISPLAY

Includes: 50W Flame height gauge and 100% absorbent cotton

UL94,IEC60695-11-4 Horizontal-Vertical Flame Tester suppliers    UL94,IEC60695-11-4 Horizontal-Vertical Flame Tester manufacturers