Digital PID temperature controller:
1)Dual PID control2)high acuracy
3)RAMB/SOAK program control
4)Valve feedback,remote SV
Port: Shanghai
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 20000 Piece/Pieces per Week
Payment Terms: L/C,T/T
Contact SupplierPackaging Detail: Each in a little box,then in a carton
Delivery Detail: according to clients requirement
MY PID micro processor temperature controller
Main Feature:
1) Auto tuning ,fuzzy PID controlling
2) 11 thermocouple & 2 analog signals input modes,self-setting
3) 2 control output:main/aux (out1/out2)
4) 13 alarm output modes self-setting
5) 3 alarm output:alarm1,alarm2,alarm3
6) Alarm with hold action
7) 16 segments programming procedure
8) Ramp and sock controller
9) 3wire system motor valve controller
10) Digital communication
Specifications:
Model | MY100 | MY400 | MY500 | MY700 | MY900 | |||||||
Size(WXHXD) | 48 x 48X80mm | 48 x 96X80mm | 96X48X80mm | 72 x 72X80mm | 96 x 96X80mm | |||||||
Power Suply | 85- 265VAC(SMPS) or DC24V,AC24V | |||||||||||
Input | TC:K,E,J,T,B,S,WU-RE 3-25,N,R | |||||||||||
RTD:Pt100, Cu50, 0~400Ω | ||||||||||||
Analog signals:DC 0~20mV,0~50mV or others DC 0~1V,0~2V ,0~5V,0~10V,1~4V,1~5V,2~10V or others DC 4~20mA,0~20mA ,0~10mA or others | ||||||||||||
AUX Input(valve feedback or remote SV):DC 4~20mA,0~10V or others | ||||||||||||
Temperature Unit:°C or °F | ||||||||||||
Output | Main output (Out1):Relay: 250VAC/5A Volt.pulse:12VDC (for solid state relay) Triac(<100A) Current:DC 4~20mA,0~20mA ,0~10mA ,0~5VDC,1~5VDC Phase SCR | |||||||||||
AUX output(Out2 cooling): Relay:250VAC/5A Volt.pulse:12VDC (for Solid State Relay) Triac(<100A) Current:DC 4~20mA,0~20mA ,0~10mA , 0~5VDC,1~5VDC | ||||||||||||
Alarm1/alarm2:Relay:250VAC/5A,250VAC/3A(MY100) | ||||||||||||
Control | Control action PID action (reverse action,for heating) PID action (Direct action, for cooling) Heat/cool PID action (heating and cooling) | |||||||||||
Control Function 1)General PID control (Standard) 2)Program control 3)Ramp/Soak control 4)Moto valve control (with valve position feedback) | ||||||||||||
Setting range Main setting range (SV):As input range P(Proportional):0~100%FUS adjustable (P1 for heating ,P2 for cooling) I(Integral):0~3600sec adjustable (I1 for heating ,I2 for cooling) D(Derivative):0~3600set adjustable (D1 for heating ,D2 for cooling) Heat-side proportioning cycle(1):1 to 100sec (1 be set if the control output is current output) Cool-side proportioning cycle (2):1 to 100sec (1 be set if the control output is current output) Alarm Mode:13 Mode Anti-reset windup (AR):1 to 100% of heat-side proportional band *4 *1.ON/OFF action control when Proportional band be set to "0(0.0)" *2.PD control when integral time be set to 0 second. *3.PI control when derivative time be set to 0 second. *4.Anti-rest: "0"setting,integral action OFF Control Mode:On/Off (sensitivity adjustable) | ||||||||||||
Accuracy | Measurement accuracy:(Max±0.3 FUS. or ±1)≤±1 digit | |||||||||||
Sampling cycle:0.25 sec. PV bias,-99~100°C or -99.9~100.0°C | ||||||||||||
General specifications | 85- 265VAC(SMPS) or DC24V,AC24V | |||||||||||
Operating ambience, -10~50,30~90%RH. | ||||||||||||
Consumed power:10VA | ||||||||||||
Weight: 0.3kg or less | ||||||||||||
Insulation insulating resistance>20MΩ500VDC, intensity 1500VAC/1 minute | ||||||||||||