1. temperature controller
2. RS485 communication
3. PID/ auto-tuning
4. universal type
5. For plastic machine, oven...
Port: Shanghai
Minimum Order Quantity: 10 Piece/Pieces
Supply Ability: 2000 Piece/Pieces per Day
Payment Terms: L/C,D/A,D/P,T/T
Contact SupplierPackaging Detail: in Cartons
Delivery Detail: 1-15 days
COM Communication Series Intelligent Temperature Controllers are specially designed for clients multifunction requirements such as temperature controlling, signal collection, center controlling and temperature recording. Based on normal intelligent temperature controller, Winpark adds RS485 I/O port and use MODBUS communication protocol. Comparing to current output, communication type is more accurate in signal collection and temperature recording and more suitable for long-distance transmission. Besides, the two-way mode is an advantage unparalleled by current transmission.
1 General Electrical Data
Rated voltage | 175V AC~250V AC |
Insulation Strength | Power supply- input: 1500V AC 1min Input-relay output: 1500V AC 1min Power supply-relay output: 1500V AC 1min |
Working Environment | Ambient temperature: 0°C ~50°C Relative humidity: 35%~85%no condensation |
Power Consumption | <=5VA |
Insulation Resistance | Input-relay output>20MW Input-power supply>20MW Power supply-relay output>20MW |
2 Measuring data
Input sensor | Thermocouple<=100 ohm RTD<=5 ohm per each conductor |
Measuring range | K (-99 ~1300) E (-99 ~600) PT100(-99-600) Cu50(-50 ~150) |
Display accuracy | 0.1 |
Tolerance | ±0.5%FS |
3. Product Model:
COM - 1 2 3 4 5 6 7 8 9
No. | Name | Explanation |
(1) | External dimensionmm3 | A: 48mm×48mm×85mm B:48mm×96mm×82mm C: 96mm×48mm×82mm D:72mm×72mm×82mm E:96mm×96mm×82mm |
(2) | Power supply | 1:linear power supply |
(3) | Main controlOUT1 Output type | 1:relay contact switch output 2:Logic electric level(to control SSR) 3:single phase SCR Zero-crossing trigger outputto control thyristor |
(4) | OUT2/ALM Output type | 0: no output 1: relay contact switch output 2: Logic electric level(to control SSR) |
(5) | Main controlOUT1 Control method | 1: PID self tuning and fuzzy control 2: stepping control |
(6) | OUT2/ALM Control method | 0:no alarm 1:upper limit deviation alarm 2:Lower limit deviation alarm (keep) 3:absolute value upward alarm 4:proportional refrigeration |
(7) | Input sensor | 1:K-99 ~1300 2:E (-99 ~600) 3:Pt100-99~600 4:Cu50 (-50 ~150 ) |
(8) | Upper limit of measuring temperature | 1:100 2:150 3:400 4:600 5:800 6:1000 7:1300 |
(9) | Display accuracy | 0: 1 1: 0.1 |