Home  >  Temperature Instruments

Temperature Controller REX / CXT 3000 Series REX-C900 - REX-C900

REX / CXT 3000 Series REX-C900, Digital Temperature Controller - more info check here: http://www.buymeasuringtools.com/Temperature-Controller-REX-CXT-3000-Series-REX-C900-10075222/

Quick Brief

Place of Origin: Zhejiang China (Mainland) Brand Name: YUMO Model Number: REX-C900 Usage: Industrial Theory: Temperature Controller

Product Features:

REX / CXT 3000 Series REX-C900

Digital Temperature Controller

Business Terms:

Port: SHANGHAI

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 1000 Piece/Pieces per Month

Payment Terms: T/T,Western Union,MoneyGram

Contact Supplier
Temperature Controller REX / CXT 3000 Series REX-C900
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: cartons

Delivery Detail: 3-5 days

Specifications and Product Details:

Digital Temperature Controller

Main Technical Index
Input
Thermocouple(TC),Resistance Temperature Detector(RTD),Standard Current and voltage signals.
DisplayProcess Value(PV),Setting Value(SV):-1999~+1999
Output( OUT1,OUT2) Alarm(Alarm1,Alarm2) Auto setting(AT) Display: LED
Control way1).PID Control(including ON/OFF, position PID and continuous PID)
(2).Auto Setting Control
AccuracyMeasurement Accuracy:±0.5%FS Compensation error of cold terminal:±2°C(amend within 0~50°C by soft)
Resolution:14bit. Sampling period:0.5Sec.
Setting RangeSetting Value(SV):same range with PV
Proportional Band(P):0~full range(ON/OFF Control when set to 0)
Integration Time(I):0~3600Sec (no integral action when set to 0)
Derivative Time(D):0~3600Sec(no derivative action when set to 0)
Proportional Period:1~100Sec
On-off control output hysteretic loop width:1~100°C(or other PV units)
Control Output(1)Currency output: DC 0~10Ma,4~20mA(RL less than 500Ω)
(2)Voltage output: DC 0-5V,1-5V(RL more than 10K)
(3)Relay output: Contact capacity:250V AC 3A(resistive load)
(4)Voltage Impulse output:0-12V(applicable for solid state relay SSR)
(5)Silicon Controlled Rectifier(SCR) output: zero-cross triggering or phase-shift triggering(resistive load)
(6)Output Contact Capacity:250V AC 3A
Alarm output2 groups output at most,12 modes
Inanlating resistanlemore than 50MΩ(500V DC)
Inanlating intensity1500V AC/min
Power consumedless than 10 VA
Work condition0~50°C,30~85RH,no corrosive gas
Weightabt.0.5Kg(CXTA type)

Model Name
1.Outline dimension: See the outline dimension picture
2.serial number
3.Control Mode
0:PID operation and auto calculating (reverse operation)
1:PID operation and auto calculating(Forward operation)
4.Input mode:Refer to input Range Table
0:TC,RTD
1:standard current 4~20mA,0~20mA
2:standard voltage:0~5V DC,1~5V DC
3:electronic sigral code:(Ω)
5.femperature unit
0:degree celsius (°C)
1:Fahrenheit (F)
6.First control output(OUT1) (Heating side)
M: Relay contact output
V: Voltage impulse output
T: Thyratron output
8: Current output(IC4-20mA)
G: Thyratron driving & triggering output
7.Second control output( OUT2) (Cooling side)
No mark: when the control mode is F or D
M: Relay contact output T: Thyratron output
V: Voltage impulse output 8: Current output(IC 4-20mA)
T: Thyratron output
8: Current output(IC 4-20mA)
8.First alarm(ALM1),

9.Second alarm (ALM2)
N:no alarm
A: Upper-limit deviation alarm
B: Lower-limit bias alarm
C: Upper/lower limit bias alarm
D: alarm in area
E: Standby upper-limit bias alarm attached
F: Standby lower-limit bias alarm attached
G: Standby upper/lower limit bias alarm
H: Upper-limit input value alarm
J: lower-limit input alarm
K: Standby upper-limit input alarm attached
L: Standby lower-limit input alarm attached

Extemal dimensin
REX-C100
CXT -3000
A
B
C
D
E
F
G
H
C100
CXTG
48
48
10
100
45
45
80
80
C400
CXTE
96
48
10
100
92
45
116
80
C410
CXTF
48
96
10
100
45
92
80
116
C700
CXTD
72
72
10
100
68
65
90
96
C900
CXTA
90
90
10
100
92
92
116
116
C800
CXTM
80
160
10
100
76
152
105
190

Temperature Controller REX / CXT 3000 Series REX-C900 suppliers    Temperature Controller REX / CXT 3000 Series REX-C900 manufacturers