REX / CXT 3000 Series CXTF-3000
Digital Temperature Controller
Port: SHANGHAI
Minimum Order Quantity: 1 Piece/Pieces
Supply Ability: 1000 Piece/Pieces per Month
Payment Terms: T/T,Western Union,MoneyGram
Contact SupplierPackaging Detail: cartons
Delivery Detail: 3-5 days
Digital Temperature Controller
Main Technical Index |
Input | Thermocouple(TC),Resistance Temperature Detector(RTD),Standard Current and voltage signals. |
Display | Process Value(PV),Setting Value(SV):-1999~+1999 Output( OUT1,OUT2) Alarm(Alarm1,Alarm2) Auto setting(AT) Display: LED |
Control way | 1).PID Control(including ON/OFF, position PID and continuous PID) (2).Auto Setting Control |
Accuracy | Measurement Accuracy:±0.5%FS Compensation error of cold terminal:±2°C(amend within 0~50°C by soft) Resolution:14bit. Sampling period:0.5Sec. |
Setting Range | Setting Value(SV):same range with PV Proportional Band(P):0~full range(ON/OFF Control when set to 0) Integration Time(I):0~3600Sec (no integral action when set to 0) Derivative Time(D):0~3600Sec(no derivative action when set to 0) Proportional Period:1~100Sec On-off control output hysteretic loop width:1~100°C(or other PV units) |
Control Output | (1)Currency output: DC 0~10Ma,4~20mA(RL less than 500Ω) (2)Voltage output: DC 0-5V,1-5V(RL more than 10K) (3)Relay output: Contact capacity:250V AC 3A(resistive load) (4)Voltage Impulse output:0-12V(applicable for solid state relay SSR) (5)Silicon Controlled Rectifier(SCR) output: zero-cross triggering or phase-shift triggering(resistive load) (6)Output Contact Capacity:250V AC 3A |
Alarm output | 2 groups output at most,12 modes |
Inanlating resistanle | more than 50MΩ(500V DC) |
Inanlating intensity | 1500V AC/min |
Power consumed | less than 10 VA |
Work condition | 0~50°C,30~85RH,no corrosive gas |
Weight | abt.0.5Kg(CXTA type) |
Model Name | |
1.Outline dimension: See the outline dimension picture 2.serial number 3.Control Mode 0:PID operation and auto calculating (reverse operation) 1:PID operation and auto calculating(Forward operation) 4.Input mode:Refer to input Range Table 0:TC,RTD 1:standard current 4~20mA,0~20mA 2:standard voltage:0~5V DC,1~5V DC 3:electronic sigral code:(Ω) 5.femperature unit 0:degree celsius (°C) 1:Fahrenheit (F) 6.First control output(OUT1) (Heating side) M: Relay contact output V: Voltage impulse output T: Thyratron output 8: Current output(IC4-20mA) G: Thyratron driving & triggering output | 7.Second control output( OUT2) (Cooling side) No mark: when the control mode is F or D M: Relay contact output T: Thyratron output V: Voltage impulse output 8: Current output(IC 4-20mA) T: Thyratron output 8: Current output(IC 4-20mA) 8.First alarm(ALM1), 9.Second alarm (ALM2) |
Extemal dimensin |
REX-C100 | CXT -3000 | A | B | C | D | E | F | G | H |
C100 | CXTG | 48 | 48 | 10 | 100 | 45 | 45 | 80 | 80 |
C400 | CXTE | 96 | 48 | 10 | 100 | 92 | 45 | 116 | 80 |
C410 | CXTF | 48 | 96 | 10 | 100 | 45 | 92 | 80 | 116 |
C700 | CXTD | 72 | 72 | 10 | 100 | 68 | 65 | 90 | 96 |
C900 | CXTA | 90 | 90 | 10 | 100 | 92 | 92 | 116 | 116 |
C800 | CXTM | 80 | 160 | 10 | 100 | 76 | 152 | 105 | 190 |