Temperature Controller Hot Plate with waterproof sensor
1.Main Features
Input free to choose thermocouple, RTD, voltage, current and expanded input and custom linear correction tables, measuring accuracy up to 0.1
Use advanced artificial intelligent control algorithm, no overshoot and with the function of auto tuning (AT) and self-adaptation, with a new fine control mode.
Use advanced modular structure, conveniently providing plentiful output options, able to satisfy the requirements of various applications, make quick delivery and convenience the maintenance of the instrument.
Emphasis on energy saves and environmental design, using high quality components to achieve low power consumption and low temperature drift, effectively saving customers energy.
The number of measurement samples per second, 12.5 times the rate of minimum control period of 0.24 seconds, to adapt to rapid changes in the object control accuracy.
Friendly and customized operating interface leads to quick and easy to operate.
Parameter can be promoted to immediate operator access in Field Parameter Table or password protected in Full Parameter Table.
With worldwide power supply of 100-240VAC or 24VDC and various installation dimensions for users to choose
Model definition
Advanced modular hardware design is utilized for Tcontroller series instrument. The instrument with enhanced lateral plate can be equipped with maximum modules of 5.There are more than ten kinds of modules, some of which are double-duty module. Modules of special function can be customized on request.
The basal Tcontroller instrument has provided many functions enough to meet different requirements asked by users. In order to expand its application bound, an optional software function is provided. The options make the instrument to be able to meet some users' special requirement. There is another manual about these options for those users with special requirement.
2.TECHNICAL SPECIFICATION
Input type: (Either of below specifications can be used selectively in the one instrument)
- Thermocouple: K, S, R, E, J, N, T, B, WRe3-WRe25, WRe5-WRe26.
- Resistance temperature detector: Cu50, Pt100
- Linear voltage: 0~5V, 1~5V, 0~1V, 0~100mV, 0~20mV, -5~5V,-1~1V,-20mV~20mVetc.
- Linear current (external precise shunt resist needed): 0~10mA,0~20mA, 4~20mA, etc.
- Optional: apart from the above-mentioned Input type, an additional type can be provided upon request. (Graduation index is needed)
Instrument Input range:
K(-50~+1300°C),S(-50~+1700°C),R(-50~+1700°C),T(-200~+350°C),E(0~800°C),J(0~1000°C),B(200~1800°C),N(0~1300°C),WRe3-WRe25(0~2300°C),WRe5-WRe26(0~2300°C)
Cu50(-50~+150°C) ,Pt100(-200~+800°C),Pt100( -100.00~+300.00°C)
Linear Input: -9990~30000 defined by user
Measurement accuracy: 0.1 (Note: The thermocouple should Cu50 copper resistance to compensate for external, internal compensation will be compensated an additional error of ± 1 °C)
Temperature shift : ≤35PPm/°C(Note: external Cu50 copper thermocouple compensation resistor, the internal compensation by an additional drift error)
Sampling period: 12.5 times per second sampling; set the digital filter parameters FILt = 0, the display response time ≤ 0.5 seconds
Control period : 0.24~300.0 seconds selectable,
Adjustment method: Position adjustment mode (adjustable hysteresis) Standard PID with auto tuning HM PID with auto tuning, adopting artificial intelligence algorithm.
Output mode (modularized):
- Relay output (NO+NC): 250VAC/1A and 30VDC/1A
- TRIAC no contact discrete output (NO or NC): 100~240VAC/0.2A (continuous), 2A (20mS instantaneous, repeat period≥5s)
- SSR Voltage output: 12VDC/30mA (used to drive SSR).
- Thyristor zero crossing trigger output: Can trigger TRIAC of 5~500A, a pair of inverse paralleled SCRs or SCR power module.
- Linear current output: 0~10mA, 4~20mA can scaling by user. (Output voltage: X3≥10.5V; X5≥7V)
- Alarm function: High limit, low limit, deviation high limit and deviation low limit; providing the function of alarm blocking at the beginning of power on.
Power supply:100~240VAC
Power consumption:≤0.5W ,Maximum Power≤4W
Operating Ambient:Temperature 0~60°C; humidity ≤90%RH
Front panel dimension:96*96mm, 72*72mm,48*96mm
Panel cutout dimension:92*92mm, 68*68mm,45*92mm
Depth behind mounting surface:≤100mm
3.Parameter Setting Flow Chart
4. FRONT PANEL AND OPERATION
Basic display status: When power on, the upper display window of the instrument shows the process value (PV), and the lower window shows the set point (SV). This status is called basic display status. Symbol description was shown as following table:
Note: The alarm message can turn off by setting parameter AdIS to oFF.
5.FRONT PANEL AND OPERATION:
Details photo of temperature controller