Home  >  Temperature Instruments

Temperature Controller CD/CH Series CH402 - CH402

CD/CH Series CH402, Heating/Cooling control, Digital communication - more info check here: http://www.buymeasuringtools.com/Temperature-Controller-CD-CH-Series-CH402-10279957/

Quick Brief

Place of Origin: Zhejiang China (Mainland) Brand Name: YUMO Model Number: CH402 Usage: Industrial Theory: Temperature Controller

Product Features:

CD/CH Series CH402

Heating/Cooling control

Digital communication

Business Terms:

Port: SHANGHAI

Minimum Order Quantity: 1 Piece/Pieces

Supply Ability: 1000 Piece/Pieces per Month

Payment Terms: T/T,Western Union,MoneyGram

Contact Supplier
Temperature Controller CD/CH Series CH402
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: cartons

Delivery Detail: 3-5 days

Specifications and Product Details:

Heating/Cooling control

Auto adjusting function

Digital communication

Big screen LED display

Industrial tandard microcomputer processor

Model Name
1.Outline dimension
See the outline dimension picture
2.Control Mode
F:PID operation and auto calculating (reverse operation)D:PID operation and auto calculating(Forward operation)
W:eating/cooling PID operation and auto calculating(cooling water)*1A:heating/cooling PID operation and auto calculating(cooling water)*1
3.Input mode
Refer to Input Range Table
4.Range Code
Refer to Input Range Table
5.First control
output(OUT1)
(Heating side)
M: Relay contact output
V: Voltage impulse output
T: Thyratron output
8: Current output(IC4-20mA)
G: Thyratron driving & triggering output
6.Second control
output( OUT2)
(Cooling side)*2
No mark: when the control mode is F or D
M: Relay contact output
V: Voltage impulse output
T: Thyratron output
8: Current output(IC 4-20mA)
7.First alarm(ALM1)
8.Second alarm (ALM2)*2
N: no alarm
A: Upper-limit bias alarm
B: Lower-limit bias alarm
C: Upper/lower limit bias alarm
D: alarm in area
E: Standby upper-limit bias alarm attached
F: Standby lower-limit bias alarm attached
G: Standby upper/lower limit bias alarm
H: Upper-limit input value alarm
J: lower-limit input alarm
K: Standby upper-limit input alarm attached
L: Standby lower-limit input alarm attached
P: Heater breakage alarm(CTL-6)*3
S: Heater breakage alarm(CTL-12)*3
R: Control line breakage alarm *4
V: Upper-limit set value alarm
W: Lower-limit set value alarm
9.Communication*5
N:No communication5:RS-485(two-wire system)
10.Water-proof/dust-proof
N:no water-proof/dust-proof1:with water-proof/dust-proof

Outline dimension

Refer to Input Range Table
Input type
Set range
Input type
Set range
Thermocouple Input(TC)
K
0 to 1372°C(0 to 2502 F)
J
0 to 1200°C(0 to 2192 F)
R
0 to 1769°C(0 to 3216 F)
S
0 to 1769°C(0 to 3216 F)
B
0 to 1820°C(0 to 3308 F)
E
0 to 1000°C(0 to 1832 F)
N
0 to 1300°C(0 to 2372 F)
T
-199.9 to +400.0°C(-199.9 to +752.0 F)
W5Re/W26Re
0 to 2320°C(0 to 4208 F)
PL
0 to 1390°C(0 to 2534 F)
L
0 to 900°C(0 to 1652 F)
U
-199.9 to +600.0°C(-199.9 to +999.9 F)
RTD Input Pt
100Ω(JIS/IEC)
-199.9 to +649.0°C
(-199.9 to +999.9 F)
JPt100Ω(JIS)
-199.9 to +649.0°C
(-199.9 to +999.9 F)
Voltage input
0 to 5V DC
1 to 5V DC
-1999 to +9999(programmable range)
Current input
0 to 20mADC
4 to 20mADC
-1999 to +9999(programmable range0)

Temperature Controller CD/CH Series CH402 suppliers    Temperature Controller CD/CH Series CH402 manufacturers