Home  >  Other Measuring & Analysing Instruments

TWCL-T Magnetic stirrer - TWCL-T

1.220v50Hz(can customize others)2 capacity50000ml,3 temperature accuracy3C 4. bear temperature 350C - more info check here: http://www.buymeasuringtools.com/TWCL-T-Magnetic-stirrer-10171857/

Quick Brief

Place of Origin: Henan China (Mainland) Brand Name: Aibote Model Number: TWCL-T color: bule size: medium

Product Features:

1.220v50Hz(can customize others)2 capacity50000ml,3 temperature accuracy3C 4. bear temperature 350C

Business Terms:

Port: Shanghai

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 20 Set/Sets per Day

Payment Terms: L/C,T/T,Western Union

Contact Supplier
TWCL-T Magnetic stirrer
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: carton

Delivery Detail: within 10 days

Specifications and Product Details:

TWCL-T magnetic stirring heating mantle

product features :

1.Use the heating mantle to warm up,with features of big heating area,balance and swift warming up,the maximum temperature can be up to 380°C.

2.Can heat and stir the standard and off-standard 50-2000ml reaction –bulbs and other canisters .

3.The shell adopts one-time forming flame retardant strengthen PBT injection moulding shell, with thermostability,anti-corrosion and good insulation property.

4.Using brushless DC motor , with stable performance ,low noise ,long service life , no spark .

5.30°cant control panel is suitable for standing and sitting viewing angle .

6.Stepless speed adjustment,low speed-stable , high speed-strong

7.Electric voltage adjustable circuit is equipped inside, controlled silicon control the temperature.

Usage

1.Fix the lever in the screw hole at the back and above of the instrument(attention :clockwise and counterclockwise ),adjust the hight of the cross clip and fasten the reaction bulb with the universal clip ,then put into a appropriate stirring pebble.Connect to the AV 220v power source and open the power switch.

2.Adjust the “stirring”knob clockwisely , make it at a right place according to the showed speed to carry out stirring .

3.If the capacity is large or the solution is thick , you can increase the stirring strength by adjusting the knob .

4.Adjust the “temperature adjustment”knob clockwisely , make it at a right place according to the needed temperature to carry out heating.

5.If needed to display the temperature,a glass thermometer or a digital thermometer can be used as auxiliary measurement.

6.If the phenomenon of jumping seed occurs , please turn off the stirring first and start slowly .

technical parameter:

1.power supply :~220∨,50Hz

2.range of speed adjustment:50-1800 rbm ,stepless speed adjustment .

3.power of motor:40W,DC14-24V

4.capacity of mixing:50,100,250,500,1000,2000,3000,5000,10000,20000ml

5.power of heating:180--2200w

6.temperature control mode: stepless voltage adjustment , controlled silicon control.

7.precision of temperature control :±3°C

8.temperature of heating :maximum surface temperature can be up to 380°C.

9.boiling time :water 10-25 minutes

10heating wire:Cr20Ni80

11.insulation layer :alkali-free glass fiber ,can bare temperature of 450°C

12.insulation coefficient :dry ≥500M

13.thermal insulation layer :exclusively using special mould to finalize the design by vacuum filtering the Aluminum silicate wool and to add glue and to dry to make the hemispherical thermal insulator .

14.working time :continuous

15 fuse pipe :ø5×20 15A

attention

1.instrument should be earthed well .(instrument should has a good earthing )

2.As the temperature resistance of the motor and the magnet is limited , in doing the heating experiment especially the high temperature heating experiment ,please make sure that the motor rotating at a low speed in order to avoid any damage to the spare parts .

3.The heating part’s temperature is very high , pay attention to it when operating , so as not to get burned .

4.At first usage ,it is normal when some white smoke and peculiar smell escapes from the instrument ,because the inner insulation material is made with some oil and other compound. At this time ,you just should put it in the tip-off place .you can use it after a few minutes smoke will disappear .

5.The heating mantle whose capacity is more than 3000ml will make noise like “creak” , this must be related to the different structure of the heating wire or controlled silicon pressure regulating the pulse signal. Please rest assured to use .

6.In case of power off , please check the fuse first at the back and above and see to it that whether it gets changed.

7.please don't use instrument without any load .

8.Please turn off the power immediately in case of any liquid spilling into the mantle . put the heating mantle in a ventilate place , when it is dry that you can use again , in order to avoid short circuit or any danger .

9.Long time no use ,please keep it clean and reserve it in a dry and without any corrosion air place .

When there is some change and difference about the specification which is caused by products or products reform related to the specification , pardon that we won’t inform you.

TWCL-T Magnetic stirrer suppliers    TWCL-T Magnetic stirrer manufacturers