1.220v50Hz(can customize others)2 capacity50000ml,3 temperature accuracy3C 4. bear temperature 350C
Port: Shanghai
Minimum Order Quantity: 1 Set/Sets
Supply Ability: 20 Set/Sets per Day
Payment Terms: L/C,T/T,Western Union
Contact SupplierPackaging Detail: carton
Delivery Detail: within 10 days
TWCL-G
products features :
1.Exclusively use aluminum made TEFLON boiler to heat ,unique heating mode (patent applied for ),can heat water to 100°C or oil to250°C .
2.Can heat the standard and off-standard 50-1000ml reaction –bulbs and other canisters .
3.Using brushless DC motor , with stable performance ,low noise ,long service life , no spark .
4.The shell adopts one-time forming flame retardant strengthen PBT injection moulding shell, with thermostability,anti-corrosion and good insulation property.
5. Stepless speed adjustment,low speed-stable , high speed-strong.
6.electronic voltage adjustment equipped inside ,controlled silicon controlling.
7.30 ° cant control panel is suitable for standing and sitting viewing angle
Usage
1.Fix the lever in the screw hole at the back and above of the instrument(attention :clockwise and counterclockwise ),adjust the hight of the cross clip and fasten the reaction bulb with the universal clip ,then put into a appropriate stirring pebble.Connect to the AV 220v power source and open the power switch.
2.Adjust the “stirring”knob clockwisely , make it at a right place according to the showed speed to carry out stirring .
3.If the capacity is large or the solution is thick , you can increase the stirring strength by adjusting the knob .
4.Adjust the “temperature adjustment”knob clockwisely , make it at a right place according to the needed temperature to carry out heating.
5.If needed to display the temperature,a glass thermometer or a digital thermometer can be used as auxiliary measurement.
6.If the phenomenon of jumping seed occurs , please turn off the stirring first and start slowly .
technical parameter
1.power supply :~220∨,50Hz
2.range of speed adjustment:50-1800 rbm ,stepless speed adjustment .
3.power of motor:40W,DC14-24V
4.capacity of mixing:50-5000ml
5.power of heating:180--1800w
6.temperature control mode: stepless voltage adjustment , controlled silicon control.
7.precision of temperature control :±3°C
8.temperature of heating :water bath 100°C, oil bath 250°C
9.boiling time :water 10-25 minutes
10heating wire:Cr20Ni80
11.insulation coefficient :dry ≥500M
12.heating boiler:ø130*60,ø190*90, ø240*150, ø310*150mm
13.working time :continuous
14. fuse pipe :ø5×20 15A
attention
1.instrument should be earthed well .(instrument should has a good earthing )
2.As the temperature resistance of the motor and the magnet is limited , in doing the heating experiment especially the high temperature heating experiment ,please make sure that the motor rotating at a low speed in order to avoid any damage to the spare parts .
3.The heating part’s temperature is very high , pay attention to it when operating , so as not to get burned .
4.In case of power off , please check the fuse first at the back and above and see to it that whether it gets changed.
5.please don't use instrument without any load .
6.Please turn off the power immediately in case of any liquid spilling into the mantle . put the heating mantle in a ventilate place , when it is dry that you can use again , in order to avoid short circuit or any danger .
7.Long time no use ,please keep it clean and reserve it in a dry and without any corrosion air place .
When there is some change and difference about the specification which is caused by products or products reform related to the specification , pardon that we won’t inform you.