TH2822A Portable LCR Meter
Portable LCR meter with frequency of 10kHz
Basic accuracy: 0.25%
40,000 counts on primary par
Port: Shenzhen
Minimum Order Quantity: 10 Piece/Pieces The more the cheaper!
Supply Ability: 600 Piece/Pieces per Month
Payment Terms: T/T,Western Union,MoneyGram,Paypal
Contact SupplierPackaging Detail: 750g/pcs,10 pcs /carton
Delivery Detail: Less than 7 days!
TH2822A Portable LCR Meter
TH2822 adopts the ultra-low dissipation design and high density SMD assembly techniques and can simultaneously display primary and secondary parameters by the use of backlit LCD display. The dual-color shells are gorgeously once shaped; functions are easy to operate. Gorgeously once shaped dual-color shells and easy operating functions are the characteristics of the meter. The test frequency is up to 1 KHz, the readings of primary parameter 40,000 counts and the resolution of dissipation factor 0.0,001. Accurate and convenient measurements of passive-components can be achieved in all occasions for a long time. With USB interface TH2822 series can conveniently make data communication and remote control with PC. In order to satisfy the increasing test requirements for SMD and balance the different needs for performance and price, two types of 4-terminal Kelvin test tweezers: TH26009C and TH26029C are available for users’ choice.
TH2822 | TH2822A | TH2822C | ||
LCR Test Parameter | Main parameters: L / C / R / Z; secondary parameters:D / Q / θ / ESR | |||
Test Frequency | 100Hz,120Hz,1kHz | 100Hz,120Hz,1kHz,10kHz | 100Hz,120Hz,1kHz,10kHz,100kHz | |
Test Level | 0.6Vrms | 0.6Vrms | 0.6Vrms | |
Output Resistance | 100 Ω | 100 Ω | 100 Ω | |
Basic Accuracy | 0.25% | 0.25% | 0.25% | |
Measuring Speed | 4 meas/sec,1.5 meas/sec | 4 meas/sec,1.5 meas/sec | 4 meas/sec,1.5 meas/sec | |
Equivalent Circuit | Series and Parallel | |||
Ranging Mode | Auto and Hold | |||
Calibration Function | Open and Short Sweep Zeroing | |||
Comparator Function | 1%,5%,10% | 1%,5%,10%,20% | 1%,5%,10%,20% | |
Interface | Mini-USB(virtual serial port ) | |||
Measuring Range | C | 0.0pF ~20.000mF | 0.00pF ~20.000mF | 0.000pF ~20.000mF |
L | 0.0uH ~ 1000.0H | 0.00uH ~ 1000.0H | 0.000uH ~ 1000.0H | |
D | 0.0000 ~ 9.999 | 0.0000 ~ 9.999 | 0.0000 ~ 9.999 | |
Q | 0.0000 ~ 9999 | 0.0000 ~ 9999 | 0.0000 ~ 9999 | |
θ(DEG) | -180°~ +180° | -180°~ +180° | -180°~ +180° | |
Z/R | 0.0000 Ω ~ 10.000 MΩ | 0.0000 Ω ~ 10.000 MΩ | 0.0000 Ω ~ 10.000 MΩ | |
ESR | 0.0000 Ω ~ 999.9Ω | 0.0000 Ω ~ 999.9Ω | 0.0000 Ω ~ 999.9Ω | |
Display | LCD Main/secondary parameters; Main parameters 40000digits, secondary parameters D / Q / θ minimum resolution 0.0001 | LCD Main/secondary parameters, backlight; | ||
Measurement Terminals | 3, 5 Terminals | |||
Power Requirements | IEC 6LR61, 9V alkaline battery | LH-200H7C, 8.4V Ni-MH 200mAH Battery | ||
Operating Current | Max.: 28mA, 1KH: 25mA(100 OHM) | |||
Standby Currant | Max.: 2μA |